Download Print this page

Omron D4BL Manual page 3

Safety-door lock switch
Hide thumbs Also See for D4BL:

Advertisement

D4BL
3. General Ratings
Rated voltage
g
125 VAC
250 VAC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
Note: 1. Resistive loads have a power factor (cos = φ) of 1.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp loads have an inrush current of 10 times the steady-state current, while motor loads have an inrush current of 6 times the
steady-state current.
4. Inrush current: NC: 30 A max.; NO: 30 A max.
H
CHARACTERISTICS
Operating speed
Operating frequency
Operating characteristics
Locked resistive pulling force
Insulation resistance
Rated insulation voltage (U
Conventional enclosed thermal current (I
continuous current)
Dielectric strength (U
Short-circuit protective device
Contact resistance
Vibration resistance
Shock resistance
Life expectancy
Ambient temperature
Ambient humidity
Operating environmental pollution level
Insulation class
Enclosure rating (See Note.)
Note: Although the switch box does not allow the penetration of dust, oil or water, keep the operation key insertion slot free of dust, oil,
and water.
Downloaded from
Elcodis.com
electronic components distributor
Non-inductive load
Resistive load
NC
NO
10 A
10 A
10 A
10 A
6 A
0.8 A
0.4 A
Positive opening
force
Positive opening
stroke
All stroke
)
i
) (rated
the
)
imp
Malfunction
Destruction
Malfunction
y
Mechanical
Electrical
Operating
Operating
g (
)
UL
NEMA
IEC529
Inductive load
Lamp load
Inductive load
NC
NO
NC
3 A
1.5 A
10 A
2 A
1 A
10 A
6 A
3 A
10 A
6 A
3 A
10 A
4 A
3 A
6 A
0.2 A
0.2 A
0.8 A
0.1 A
0.1 A
0.4 A
0.05 to 0.5 m/s
30 operations/min max.
19.61 N (4.41 lbf) min.
20 mm (0.79 inch) min.
23 mm (0.91 inch) min.
700 N (157 lbf) min.
100 MΩ min. (at 500 VDC)
300 VAC
10 A
Impulse dielectric strength (U
imp
different polarity, between each terminal and ground, and between each terminal
and non-current-carrying metal part; 2.5 kV between solenoid and ground
10 A fuse (type gl) (IEC269)
50 mΩ max. (initial value)
10 to 55 Hz, 0.35-mm single amplitude with an imposed acceleration of 50 m/s
(5G) max. (IEC68-2-6)
2
1,000 m/s
(100G) min. (IEC68-2-27)
2
300 m/s
(30G) min. (IEC68-2-27)
1,000,000 operations min.
500,000 operations min. (with a load rate of 0.5)
–10 to 55 C (14 to 131 F) with no icing
95% max.
Pollution degree 3 (IEC947-5-1)
Insulation class I (IEC536)
6P and 13
6P and 13
IP67 (60947-5-1)
Motor load
NO
NC
5 A
3 A
6 A
6 A
4 A
0.2 A
0.1 A
) 4 kV (IEC 947-5-1) between terminals of
D4BL
NO
2.5 A
1.5 A
2
3

Advertisement

loading