Bosch Climate 5000 Series Service Manual page 90

Ducted type (medium & high static) air conditioner / heat pump
Hide thumbs Also See for Climate 5000 Series:
Table of Contents

Advertisement

Service Manual
6. Then remove the electronic control board (4 hooks).
Figure 144
PCB Board 11
1. Disconnect the connector for compressor and release the ground wire(1
screw).
Figure 145
2. Pull out the wires from electrical supporting plate and turn over the electronic
control assembly.
9 0 |
Bosch Climate 5000 Series Ducted Type (Medium & High Static) Air Conditioner / Heat Pump (11.2022)
Figure 146
3. Remove the electronic installing box subassembly (4 hooks).
Figure 147
4. Remove the fi xing board (2 hooks).
Figure 148
5. Disconnect the connectors from the electronic control board.