Dell PowerEdge C6620 Installation And Service Manual page 40

Table of Contents

Advertisement

Table 36. Network Settings details (continued)
Option
UEFI HTTP Settings
HTTP Device n (n = 1 to 4)
HTTP Device n Settings (n = 1 to 4)
UEFI iSCSI Settings
iSCSI Initiator Name
iSCSI Device1
iSCSI Device1 Settings
UEFI NVMe-oF Settings
NVMe-oF
NVMe-oF Host NQN
NVMe-oF Host Id
Host Security Key Path
NVMe-oF SubSystem Settings (n = 1 to 4)
Table 37. TLS Authentication Configuration screen details
Option
TLS Authentication Mode
Root Certificate Configuration
Table 38. NVMe-oF SubSystem Settings screen details
Option
NVMe-oF SubSystem n (n = 1 to 4)
NVMe-oF SubSystem n Settings (n = 1
to 4)
40
Pre-operating system management applications
Description
Enables you to control the configuration of the UEFI HTTP device.
Enables or disables the device. When enabled, a UEFI HTTP boot option is
created for the device.
Enables you to control the configuration of the HTTP device.
Enables you to control the configuration of the iSCSI device.
Specifies the name of the iSCSI initiator in IQN format.
Enables or disables the iSCSI device. When disabled, a UEFI boot option
is created for the iSCSI device automatically. This is set to Disabled by
default.
Enables you to control the configuration of the iSCSI device.
Enables you to control the configuration of the NVMe-oF devices.
Enables or disables the NVMe-oF feature. When enabled, it allows to
configure the host and target parameters needed for fabric connection.
This is set to Enabled by default.
This field specifies the name of the NVMe-oF host NQN. Allowed input is
in the following format: nqn.yyyy-mm.<Reserved Domain Name>:<Unique
String>. Leave it empty to use system generated value with following
format: nqn.1988-11.com.dell:<Model name>.<Model number>.<Service
Tag>. This is set to nqn.1988-11.com.dell:<model name>.<model
number>.<service tag> by default.
This field specifies a 16 bytes value of the NVMe-oF host identifier
that uniquely identifies this host with the controller in the NVM
subsystem. Allowed input is a hexadecimal-encoded string in this format:
00112233-4455-6677-8899-aabbccddeeff. Leave it empty to use system
generated value. A value of all FF is not allowed. This is set to
FFFFFFFF-FFFF-FFFF-FFFF-FFFFFFFFFFFF by default.
This field specifies the Host security key path.
This field controls the parameters for the NVMe-oF subsystem n
connections.
Description
View or modify the device's boot TLS Authentication Mode. This option is set to One
Way by default. None means the HTTP server and the client will not authenticate each
other for this boot.
Import, delete, or export the root certificate.
Description
Enables or disables NVMe-oF SubSystem. This option is set to Disabled by
default.
Enables you to control the configuration of the NVMe-oF SubSystem, if Enabled.

Advertisement

Table of Contents
loading

This manual is also suitable for:

E81s

Table of Contents