Iso; Rohs; Emc And Environmental Type Tests - Siemens SIMATIC NET RUGGEDCOM RS8000H Installation Manual

Rugged ethernet switches
Table of Contents

Advertisement

6.1.5

ISO

This device was designed and manufactured using a certified ISO (International
Organization for Standardization) quality program that adheres to the following
standard:
6.1.6

RoHS

This device is declared by Siemens Canada Ltd. to meet the requirements of the
following RoHS (Restriction of Hazardous Substances) directives for the restricted use
of certain hazardous substances in electrical and electronic equipment:
A copy of the Material Declaration is available online at
support.industry.siemens.com/cs/ww/en/view/109738831.
6.2

EMC and Environmental Type Tests

The RUGGEDCOM RS8000H has passed the following EMC and environmental tests.
IEC 61850-3 Type Tests
61000-4-2
61000-4-3
61000-4-4
61000-4-5
RUGGEDCOM RS8000H
Installation Manual, 11/2022, C79000-G8976-1022-07
ISO 9001:2015
Quality management systems – Requirements
China RoHS 2
Administrative Measure on the Control of Pollution Caused by Electronic
Information Products
Test
IEC
ESD
IEC
Radiated RFI
IEC
Burst (Fast Transient)
IEC
Surge
Description
Enclosure
Contact
Enclosure Air
Enclosure
ports
Signal ports
DC Power
ports
AC Power
ports
Earth
ground ports
Signal ports
DC Power
ports
AC Power
ports
Certification
https://
Test Levels
±8 kV
±15 kV
20 V/m
±4 kV @ 2.5 kHz
±4 kV
±4 kV
±4 kV
±4 kV line-to-earth,
±2 kV line-to-line
±2 kV line-to-earth,
±1 kV line-to-line
±4 kV line-to-earth,
±2 kV line-to-line
6.1.5 ISO
Severity
Levels
4
4
x
x
4
4
4
4
3
4
27