Bulk Oil Supply - Henny Penny OFE 51X Service Manual

F5 / electric
Table of Contents

Advertisement

Henny Penny
returns to the OMS PCB, then the filter pump is energized to transfer drained oil to the bulk dis-
pose tank. When the user releases the bulk dispose switch, the filter pump will stop.
24 volt DC signal from OMS to normally open switch
l
Bulk dispose switch is actuated closed by user
l
24 volt DC signal returns to OMS PCB and filter pump energized
l

Bulk Oil Supply

Control Configuration
Supply Connection
A flexible supply oil line external to the F5 fryer connects to the bulk oil system plumbing. Depend-
ing on bulk oil system type and fryer configuration, the flexible supply oil line will be either sup-
plied by Henny Penny or the bulk oil system vendor. Vendor supplied bulk oil supply hose would
have a threaded connection to the fryer rear.
Prompts
Bulk supply or fill sequences are user initiated through the F5 control panel manually. The F5 con-
trol system has no provision for automatic prompting of bulk oil fill sequences. During the on-
screen bulk fill control prompts the user is provided a choice whether to fill a vat manually or via
the bulk system.
Bulk Oil System Sequence of
F5/ LOV 300 Open Fryer