Nortel Agent Greeting NTVQ09AB Maintenance And Troubleshooting Manual page 32

Nortel agent greeting ntvq09ab: instruction manual
Hide thumbs Also See for Agent Greeting NTVQ09AB:
Table of Contents

Advertisement

Page 38 of 66
Agent Greeting Application Upgrades
NTPH13AA_maint
Checksum = 0xb018e178
length = 0x4cd434
Verifying upgrade ...
Upgrade completed OK
Reboot the pack to run new loadware
0xf1de98 (tShell):
That's all folks! Rebooting in 2 mins
Rebooting Pack ...
Where "/A:/vpsLoad" is the location of the VPS(NTVQ09AB) loadware file
copied onto the PC Card and "/A:/mcLoad" is the location of the Media Card
(NTVQ09BA) loadware file copied onto the PC Card.
The Server card transfers the correct loadware onto each card in the group.
Each card then automatically upgrades to the new loadware and reboots.
STEP8: Re-enable all cards from overlay 32 on the switch software.
STEP9: When all cards are rebooted, remove the original loadware files that
were transferred onto the server card. From the server card shell type:
rm "/A:/mcLoad" <CR>
rm "/A:/vpsload.mms" <CR>
Where "/A:/mcLoad" and "vpsLoad.mms" are the application loadware files.
STEP10: When the cards have rebooted completely, at the shell, type:
swInfoGet <CR>
This will return the version of the software currently running on the card
e.g.: Nortel Networks Agent Greeting (Media Card): 03.01
or
Nortel Networks Agent Greeting (VPS Card): 03.01
3.01
February 2006
18/08/04 11:48:24,85 * Warning *[Keycode]