Meritor TACTX HMIS Maintenance Manual page 25

High-mobility independent suspension height control system
Table of Contents

Advertisement

Section 4
Figure 4.22
5. Click the Program Device button. The screen
will display the status of the download.
Figure 4.23.
Figure 4.23
6. Once the Status displays "Programming
Completed Successfully!", the software has
been correctly uploaded to the SHC module.
Figure 4.24.
Meritor Maintenance Manual MM-0997 (Revised 12-09)
4008049a
Figure 4.24
Upload Software — Advanced Method
The advanced method is used when updating
software in the module and there is a need to
overwrite existing parameters in the SHC module.
To upload software to the SHC module using the
advanced method:
1. On the Software Management screen, click the
Advanced Tab.
2. In the "PCU #" drop-down list, select "PCU 1".
3. In the "Subnet #" drop-down list, select "Subnet
0". Figure 4.25.
4008050a
Figure 4.25
4. In the Software Folder, click the Open file
button and navigate to the directory
C:\Program Files\ArCom\Software. Once in
this directory, click the Current Folder button.
5. Select the software to be uploaded to the SHC
module from the Available Software list.
Diagnostics
4008051a
4008052a
Page 23