Version 1.00
Both SLK and phone status icons are updated with the new IP Phone 2007 icon.
Fixes in the USB driver allow more USB devices.
The TFTP now downloads the IP Phone 2007 configuration file (i2007.cfg) from the
server first, in order to determine the filename and which server IP to download from.
This new process ensures correct information is used to handle the download.
Problems with the CStr used by the editbox – strange characters, for example – are fixed.
Problems with skin controls are fixed.
A problem where the soft keyboard incorrectly translated clicks from outside the keyboard
range is now fixed.
An added debouncing feature filters out phantom clicks on the touch panel.
The icons for the service and expand keys are switched to their proper icons.

Changes in C11 (from C10):

The driver for second flash is fixed.
Changes in contrast control circuit improve the contrast range for new hardware revision.
Changes to the EEPROM map defaults allow contrast setting to adapt for new hardware
revision.
The HSS clock is enabled for new hardware revision (used by PLD).
Changes to the AEC parameters are inherited from D8x.
Application now includes an LCDtest, as requested by Wistron.
The prompts now show GXAS instead of GNet6.
The self-test from the Wistron input is fixed.
The flash base address in the self-test is fixed from 0xba000000 to 0xbf000000.
Unresponsive menu items are fixed.
For consistency in layout, the edit button in both NDU and preference tools is moved
down.
A problem with the flash file system caused the IP Phone 2007 – with C10 firmware – to
crash on startup. This problem occurred when the user changed the button
customization tool to use custom text labels, then power cycled the IP Phone 2007; the
phone then crashed, and remained in that state until upgraded to C11 or above.

Changes in C10 (from C09):

Added support for UNIStim firmware download allows messages in application to go to
BootC.
The contrast/brightness setting is now stored in EEPROM. Limits on the contrast setting
keep the display from getting too bright. (Q01024504, Q01023432)
Cursor support in infoline is added. (Q01024047, Q01026454)
The graphical XAS now supports text entering from the keyboard.
The Feature Key Label Tool for BCM is added. This addition also address the CP
Q01039716, a major new feature.
Pressing the goodbye key in the NDU left the wrong softkey. (Q04045033)
The one-way speech problem from CR Q01041635 is fixed.
C23 Firmware for Verification