Delta AC MAX Installation And Operation Manual page 19

Eu-basic version
Table of Contents

Advertisement

2.2.6.1 Pin definition
User can connect the external component with signal cable based on following configuration. The output power
will be adjusted by the following pin definition once the grid power is limited by network operator. The power
limitation is based on rated output power configured by dip switches (2.2.4.4).
2.2.6.1.1
Configuration A
Connect the signal cable with Pin 1 and Pin 5 as below:
Pin 2
Low
Low
2.2.6.1.2
Configuration B
Connect the signal cable with Pin 1 to Pin 5 as below:
Pin 3
Pin 4
Low
Low
Low
Low
19
Pin 5
Power limitation
Low
Output 100% power
High
Stop charging