Advertisement

Quick Links

Installation and operation manual
AC MAX
NA-Smart version
Version: 1.0.1
Issue date: 2022-02

Advertisement

Table of Contents
loading

Summary of Contents for Delta AC MAX

  • Page 1 Installation and operation manual AC MAX NA-Smart version Version: 1.0.1 Issue date: 2022-02...
  • Page 2: Table Of Contents

    v1.0.1 Table of Contents Information ..........................3 Copyright ........................3 Intended use ....................... 3 Important safety instructions ..................3 Operator‘s duty of supervision ..................5 EMC Compliance Statement ..................5 Model series ....................... 7 Product overview ......................8 Installation ..........................11 Prepartion before start ....................
  • Page 3: Information

    The ownership and all intellectual property rights of this Installation and Operation Manual (this “Manual”), including but not limited to the content, data and figures contained herein are vested by Delta Electronics, Inc. (“DELTA”). The Manual can only be applied to operation or use of the device. Any disposition, duplication, dissemination, reproduction, modification, translation, extraction or any other usage to the Manual is prohibited without obtaining DELTA’s prior written permission.
  • Page 4 Any repair work as well as the replacement of components on the EVSE may only be carried out by  DELTA. Otherwise the warranty will become void. Damaged or illegible safety labels must be replaced.  The EVSE can only be installed by licensed contractors, or licensed electricians in accordance with all ...
  • Page 5: Operator's Duty Of Supervision

    Warning notices, warning symbols and other markings attached to the EVSE by DELTA must not be  removed. Operator‘s duty of supervision As the operator of the EVSE, you are responsible for the safety of the users and its proper use.
  • Page 6 v1.0.1 Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  Consult the dealer or an experienced radio/ TV technician for help. ...
  • Page 7: Model Series

    v1.0.1 Model series The following describes the segmentation used to describe the basic features of each available model: EIAW - X XXK X X X X X XX 3 4 5 6 7 Segment Item Description E: AU/NZ, EMEA, SEA, G: China J: Japan Indicate the available region...
  • Page 8: Product Overview

    v1.0.1 Product overview Scope of delivery Part Description Part Description EVSE Mounting bracket Template Torx T30 mounting bolts No. 8 wood screws 1/4 inch expansion bolts Quick installation guide Safety instructions...
  • Page 9 v1.0.1 Part Description Part Description Cable holder wood screws RFID Recommended tools The following tools are recommended for the installation of product: Part Description Electro drill Used for masonry walls Pencil Spirit level Terminal crimper Crimping input wire Torque wrench Torque screwdriver (cross) Securing mounting bracket to masonry walls or stand Torque screwdriver (slotted)
  • Page 10 v1.0.1 3. Upstream breakers: CAUTION To reduce the risk of fire, connect only to a circuit provided with 60 or 100 amperes maximum branch circuit overcurrent protection in accordance with the National Electrical Code, ANSI/NFPA 70, and the Canadian Electrical Code, Part 1, C22.1. Model Circuit breaker specification EIAW-U11K...
  • Page 11: Installation

    Before you start, please read the following instructions: Prepartion before start Installation site selection AC MAX can be installed in both indoor and outdoor environments. It is necessary to consider the installation conditions and protection at the site: Follow local electrical regulation and installation standards.
  • Page 12: Installation Steps

    v1.0.1 Recommended installation space Installers shall follow applicable accessibility requirements for the mounting position. This device shall be mounted at a sufficient height from grade such that the height of the storage means for the coupling device is located between 800 mm (31.5 inches) and 1200 mm (48 inches) from grade. Front view Top view Installation steps...
  • Page 13 v1.0.1 3. Remove the screw located at the middle cover by using a Torx T20 screwdriver. 4. Remove the middle cover. (Optional) insert SIM card for cellular function Insert the SIM card into the socket and ensure the connection is well connected. Mark drill holes The EVSE is a stationary wall-mounted equipment.
  • Page 14 v1.0.1 Secure mounting bracket The cable holder is optional and depicted in the figure for demonstration purposes. The following are recommended bolt types: Masonry walls: 1/4" expansion bolts.  Torque: 8.8 N·m (78 lb·in) Finished walls supported by wood studs: #8 wood ...
  • Page 15 v1.0.1 2.2.5.1 Authorization mode Choose the pin 2 to configure the authorization mode for bluetooth availability. Configuration Function Configuration Function Not available Bluetooth* (Default) *Bluetooth connection is reserved for commissioning purpose.
  • Page 16 v1.0.1 2.2.5.2 Maximum current setting Choose the pin 4-6 to configure the maximum output current ratings. Configuration Max. Current Ratings Configuration Max. Current Ratings 10A (Default) 60A* 70A* 80A* * Depends on model configuration...
  • Page 17 v1.0.1 Connect input wire Install the copper wire as described. The section of copper wire connected to terminal shall be reserved enough tolerance to prevent any tension or stress from the external force. Note: Rated current Copper wire type 48 A 4 AWG, 90 80 A 2 AWG, 90...
  • Page 18 v1.0.1 (Optional) connect RJ45 port for Ethernet function 1. Remove the water proof cap and pass through the Ethernet cable with appropriate conduit or cable gland. 2. Connect the Ethernet cable into the RJ45 port. Secure middle cover and front cover 1.
  • Page 19: Commissioning

    Torx T20 screwdriver. Torque: 0.5 N·m (4.4 lb·in) Commissioning AC MAX can use the Web Configuration Tool to do the configuration, firmware upgrade, log download, etc. General process: 1. Finish the installation process and power on the EVSE.
  • Page 20 1. Click network icon in the Taskbar. Open “network and internet setting” and choose the connected network.(SSID: Delta-serial number/ Password: please refer to the last page of “Quick Installation Guide”) Note: serial number refers to the spec label on EVSE.
  • Page 21: Login

    v1.0.1 Login 1. Open web browser. Note: recommended web browser includes Chrome 67, safari 11, IE 10, Firefox 61 and above version. 2. Enter the web address and login. Web address: 192.168.123.123 (Ethernet)/ 192.168.5.1(WiFi) User account: admin Password: please refer to the last page of “Quick Installation Guide” Only allow 5 times “Failed login attempts”...
  • Page 22: Configuration

    v1.0.1 Configuration Operating without OCPP system User can configure the below information for EVSE: Item Description Authentication Choose the authorized mode for user authentication. Default will be “RFID mode”. Maximum charging time Choose the maximum charging time for each charging session. Default will be “No limit”.
  • Page 23 v1.0.1 For communication setting, please refer to below section. Users are able to connect the OCPP system through either “Ethernet”, “WiFi”, or “Cellular” connection. 3.3.2.1 Connection through “Ethernet” Choose the “Network mode”, and enter the corresponding information.
  • Page 24 v1.0.1 3.3.2.2 Connection through “WiFi” Enter the information based on your wireless AP setting. 3.3.2.3 Connection through “Cellular” Enter the information based on your contract with telecom operator.
  • Page 25: Edit Password

    Description Firmware update User can get the latest or improved function through firmware update, and please contact the local dealer or DELTA service partner for the support. Log download User can download the log file to analyze the EVSE status.
  • Page 26 Firmware update Press the button ”Browser Files(s)”. Choose the correct path and file to upload. Note: please contact the local dealer or DELTA service partner for the latest firmware file.
  • Page 27 v1.0.1 Press the button “Upload and restart charger” to start uploading. Uploading the file. After uploading, EVSE will restart automatically.
  • Page 28 Log download Press the button “Log download” to get the log file. Note: user may describe your question and copy the file when contacting the local dealer or DELTA service partner. Factory reset User can restore the EVSE to factory setting by pressing the button “Restore passwords to default values...
  • Page 29: Forgot Password

    v1.0.1 Forgot password If user forgot the password, please follow below to recover. 1. Click the “Forgot Password.?”. 2. Click the button “Restore passwords to default values” 3. Confirm if the user want to reset the password. After clicking the button “Yes”, the EVSE will restart automatically.
  • Page 30: Operation

    v1.0.1 Operation Turn on the upstream breaker. The indicator flashes in yellow during a system self-test. After the self-test completed, the indicator illuminates in blue and the EVSE is ready to charge. Start charging 1. Connect the vehicle connector to vehicle inlet. 2.
  • Page 31: Fault Events

    v1.0.1 Fault events Status Description Action The EVSE will be auto-recovery once the voltage is High/under voltage Red, 1 Flash normal. If not, please restart the EVSE or contact protection customer support. Red, 2 Flashes Ground fault protection. Check the ground system, and wait for recovery. Ground does not correctly Red, 3 Flashes Check if ground (PE) is well connected.
  • Page 32: Troubleshooting

    v1.0.1 Troubleshooting Contact Customer Support if the EVSE appears to malfunction or if the LED indicators display a fault event. DO NOT open the EVSE, touch or remove the circuit protective devices or any other component. Situation Action 1. Make sure the power input is connected correctly and the power is within operating range of the unit.
  • Page 33: Specifications

    v1.0.1 Specifications Version Smart Model name EIAW-U11KSSU7A04 or EIAW-U19KSSU7A04 Charge method AC level 2 Charging interface SAE J1772 Input/output rating 208-240 Vac, 1-phase, 48 or 80 A max., 60 Hz Input wiring 1-phase: L1, L2, PE Grounding system TT/TN Standby power <...
  • Page 34: Moving, Transportation And Storage

    Defects or damage caused by not using the product as specified in the Installation and Operation Manual.  Costs and damage caused by repair work which is not provided by DELTA approved authorized specialist  or electrician.

Table of Contents