Masonry Chimney; Masonry Fireplace; Factory Built Chimney - Regency F2500 Manual

Wood medium stove
Hide thumbs Also See for F2500:
Table of Contents

Advertisement

MASONRY
CHIMNEY
Ensure that a masonry chimney meets the
minimum standards of the National Fire
Protection Association (NFPA) by having it
inspected by a professional. Make sure there
are no cracks, loose mortar or other signs of
deterioration and blockage. Have the chimney
cleaned before the stove is installed and
operated. When connecting the stove through a
combustible wall to a masonry chimney, special
methods are needed.
Ensure that an effective vapour barrier at the
location where the chimney or other component
penetrates to the exterior of the structure.
When referencing installation or connection to
masonry fireplaces or chimneys, the masonry
construction must or shall be code complying.
This unit is designed to use either a 5.5"
(140mm) or 6" (152mm) flue liner only in the
confines of the masonry chimney.
MASONRY
FIREPLACE
There are listed kits available to connect a stove
to a masonry fireplace. The kit is an adapter
that is installed at the location of the fireplace
damper. The existing damper may have to be
removed to allow installation.
Ensure that an effective vapour barrier at the
location where the chimney or other component
penetrates to the exterior of the structure.
This unit is designed to use either a 5.5" (140mm)
or 6" (152mm) flue liner only in the confines of
the masonry chimney as shown.
When referencing installation or connection to
masonry fireplaces or chimneys, the masonry
construction must or shall be code complying.

FACTORY BUILT CHIMNEY

When a metal prefabricated chimney is used, the manufacturer's installation instructions must be followed. You must also purchase and install the
ceiling support package or wall pass-through and "T" section package, firestops (where needed), insulation shield, roof flashing, chimney cap, etc.
Maintain proper clearance to the structure as recommended by the manufacturer. The chimney must be the required height above the roof or other
obstructions for safety and proper draft operation. The space heater is to be connected to a factory-built chimney conforming to CAN/ULC-S629,
Standard for 650
C Factory-Built Chimneys.
0
Minimum
18"
(457mm
)
to
centerline
Minimum 18" (457mm)
to centerline
F2500 Wood Stove |
7