l During onsite operations, ensure that optical fibers are force-free and the bend
radius is greater than 40 mm. Otherwise, services may become abnormal or even
fail due to degraded signal transmission.
l The fiber strength member must be securely grounded. In addition, the ground
point of the fiber strength member must be at least 3 meters above the ground
(which prevents manual touching), and no combustible materials are around the
ground point within a distance of 0.3 m. If the fiber strength member fails to be
securely grounded, it must be insulated. Otherwise, the fiber strength member
may introduce heavy currents if it connects to a heavy-current power line,
threatening human safety.
b.
Grounding solution 2: The fiber strength member is grounded inside a
network box.
The fiber strength member must be connected to a ground bar at the ground point
using a ground cable. The ground point can connect to the network box using a
metal in an equipotential manner. When the fiber strength member connects to a
heavy-current power line, heavy currents may be discharged inside the network box
using the ground bar. If this happens, sparks may occur at the contact point between
the fiber strength member and the ground bar, which may burn the device and the
network box. To prevent this issue from occurring, use solution 1.
NO TICE
If the ground bar of the network cabinet fails to securely ground, ensure that the
fiber strength member is disconnected from the ground bar and that the fiber
strength member is properly insulated. Otherwise, heavy currents may be
discharged using the network ports on the local and peer devices, which may
damage these network ports.