Adjusting the gas oven burner's minimum setting:
1. Light the burner ( see Start-up and Use ).
2. Turn the knob to the minimum position (MIN) after
it has been in the maximum position (MAX) for
approximately 10 minutes.
3. Remove the knob.
4. Tighten or loosen the adjustment screws on the
outside of the thermostat pin ( see figure ) until the
flame is small but steady.
! If the appliance is connected to liquid gas, the
bypass screw must be adjusted to minimum.
5. Turn the knob from the MAX position to the MIN
position quickly or open and shut the oven door,
making sure that the burner is not extinguished.
Adapting the grill
Replacing the grill burner nozzle:
1. Remove the oven burner
after loosening screw V ( see
figure ).
V
I
! Be careful of the spark plug wires and the
thermocouple tubes.
! The oven and grill burners do not require primary
air adjustment.
! After adjusting the appliance so it may be used
with a different type of gas, replace the old rating
label with a new one that corresponds to the new
type of gas (these labels are available from
Authorised Technical Assistance Centres).
! Should the gas pressure used be different (or vary
slightly) from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet hose in
accordance with current national regulations relating
to "regulators for channelled gas".
Table of burner and nozzle specifications
Burner
Diameter (mm)
Oven
Grill
Rapid (R)
100
Semi Rapid
(Medium) (S)
Auxiliary
(Small) (A)
Supply
Pressures
*with dry gas 15°C 1013 mbar
** Propane P.C.S=50,37 MJ/Kg
*** Butane P.C.S=49,47MJ/kg
Natural G20 P.C.S=37,78Mj/m³
2. Unscrew the grill burner
nozzle using a special nozzle
socket spanner ( see figure ) or
preferably with a 7 mm socket
spanner, and replace it with a
new nozzle that is suited to the
new type of gas ( see Burner
and nozzle specifications table
Liquid Gas
Thermal Power
kW (p.c.s*)
Nominal
Reduced
-
2.60
1.00
-
2.20
2.00
3.00
0.70
75
2.00
0.40
55
1.00
0.40
Nominal (mbar)
Minimum (mbar)
Maximum
Flow*
By-Pass
Nozzle
g/h
1/100
1/100
(mm)
(mm)
***
**
50
79T2A
189
186
-
78 T2A
160
157
41
86
218
214
30
70
145
143
30
50
73
71
28-30
37
20
25
35
45
10
Natural Gas
Thermal Power
Nozzle
kW (p.c.s*)
1/100
Nominal
Reduced
(mm)
2.60
0.70
112 T2
2.20
1.50
110 T2
3.00
0.70
116
2.00
0.40
103
1.00
0.40
79
Flow
l/h
248
209
286
190
95
20