6. EtherNet/IP Settings
This section describes the specifications such as communication parameters and tag data link
that are set in this document.
6.1. EtherNet/IP Communications Parameters
The communications parameter required connecting the PLC and the FZ5 Sensor Controller
via EtherNet/IP is given below.
Unit number
Node address
IP address
Subnet mask
6.2. Allocating the Tag Data Links
The tag data links are allocated for the FZ5 Sensor Controller as shown below.
D10000
D10009
Additional Information
For details on the control output, command codes, and response codes, refer to Memory
Allocation in Section 2 Methods for Connecting and Communicating with External Devices -
Communicating with EtherNet/IP of the Vision Sensor FH/FZ5 Series Vision System User's
Manual (Communications Settings) (Cat. No. Z342).
PLC (EtherNet/IP Unit)
(node 1)
0
1
192.168.250.1
255.255.255.0
Output area
(PLC to
FZ5 Sensor Controller)
20 bytes
6.EtherNet/IP Settings
FZ5 Sensor Controller
(node 2)
-
2
192.168.250.2
255.255.255.0
Input area
D10100
(FZ5 Sensor Controller to
D10123
48 bytes
PLC)
7