Troubleshooting - Lincoln Electric OPTIMARC CV355P Operator's Manual

Table of Contents

Advertisement

C-1
CAUTION
Observe all Safety Guidelines detailed in the beginning and throughout this manual.
Problems (Symptoms)
Output Problems
Major physical or electrical
damage is evident when
the sheet metal covers are
removed.
Machine will not power up
(no lights, no fan, etc.)
Thermal LED is lit.
Machine won't weld, can't get
any output.
Machine won't produce full
output.
Machine often "noodle"
welds (output is limited to
approximately 100 amps)
General degradation of the
weld performance
The 4-step mode is not
available

TROUBLESHOOTING

If for any reason you do not understand the test procedures or are unable to
perform the tests/repairs safely, contact your local authorized Lincoln Electric
Field Service Facility for technical assistance.
Possible Areas of Misadjustment(s)
None
1. Make certain that the power to the
machine is energized and is within the
machine's operating range.
1. Check for proper fan operation. (Fan
should run whenever output power is
on.) Check for material blocking intake
or exhaust louvers, or for excessive dirt
clogging cooling channels in machine.
2. Machine may have been operated
above it's duty cycle..
1. Input voltage is too low or too high. Make
certain that input voltage is proper,
according to the Rating Plate.
2. If the Thermal LED is also lit, see
Thermal LED is Lit section.
3. If an error code is also present.
1. Input voltage may be too low, limiting
output capability of the power source.
Make certain that the input voltage is
proper, according to the Rating Plate.
2.
Secondary current or voltage is not
properly calibrated.
Secondary current limit has been
exceeded, and the machine has phased
back to protect itself.
1. Check for feeding problems, bad
connections, excessive loops in
cabling, etc.
2. Verify weld mode is correct for
processes.
3. The power source may require
calibration.
1.
Verify the CRATER ON/OFF toggle switch
on the front panel of machine is at ON
position.
2.
Verify the parameter of crater current and
voltage are set properly.
3.
PC board in machine possibily at fault.
OPTIMARC
Recommended Course of Action
Contact your local
authorized Lincoln Electric
Field Service facility for
technical assistance.
In a typical installation the
main power switch on the
controller is the power
switch.
Clear obstruction or repair
fan
After machine has cooled,
reduce load, duty cycle, or
both
Contact your local
authorized Lincoln Electric
Field Service facility for
technical assistance.
Correct input voltage level.
Contact your local
authorized Lincoln Electric
Field Service facility for
technical assistance.
Adjust procedure or reduce load
to lower current draw from the
machine.
If the machine need calibration,
contact an authorized Lincoln
Electric Service facility for
technical assistance.
If PC board in machine is at
fault, contact an authorized
Lincoln Electric Service facility
for technical assistance.
®
CV355P
C-1
Rev.01