12 - OPTIONS
Options
No.
Welded connection
sleeve for
304
desuperheater
305A Free cooling hydraulic coils on the two
Free cooling (total)
305B Free cooling hydraulic coils on a refrigerant
Free cooling (partial)
Free-Cooling Glyco
305C
Free (Total)
Free-Cooling Glyco
305D
Free (Partiel)
Water buffer tank
307
module
Free cooling
drycooler
313
management
Compliance with
318
UAE regulations
Compliance with
319
Qatar regulations
Water collection
325A
vessel
Installation or
application process
326
outside Europe
Compliance with
327
Moroccan regulations
Delivered in plastic
331
film
IT neutral system
333
12.2 - Description
12.2.1 - Hydraulic module without variable speed
(Options 116R, 116S, 116T, 116U)
The hydraulic module is composed of the system's main hydraulic
components: factory-fitted water pump, screen filter and relief
valve.
The fixed-speed operating pressure pump provides the nominal
flow rate for the system water loop.
Several types of water pump are available to suit all applications:
■ Single or dual low pressure pumps
■ Single or dual high pressure pumps.
The nominal flow rate of the system should be adjusted using
a manual control valve provided by the customer.
The relief valve placed on the water inlet pipes at the pump inlet
limits the pressure to 400 kPa (4 bar).
A screen filter that can be easily removed is placed at the pump
inlet and protects the pump and the plate heat exchanger against
solid particles that are greater than 1.2 mm.
Additional options can be ordered if necessary:
■ Option 42A (42B if option 307): hydraulic module protection
(42A) or hydraulic module and buffer tank protection (42B)
down to an outdoor temperature of -20 °C.
■ Option 293: Expansion tank for water circulation system.
68
Description
DSH inlet/outlet welded connection sleeves Easy installation
refrigerant circuits
circuit
Free cooling hydraulic coils on both
refrigerant circuits and decoupling
exchanger.
Free cooling hydraulic coils on one
refrigerant circuit and decoupling
exchanger.
Built-in water buffer tank module
Control and connections to a Free Cooling
drycooler 09PE or 09VE fitted with option
FC control box
Additional label on the unit with input power,
current and EER under rated conditions in
accordance with AHRI 550/590
Specific name plate on the unit
with 415 V +/-6% power supply
Pipe system providing a single hydraulic
connection point
Specific management of option compatibility Permits non-standard option compatibility
Specific regulatory documentation
Plastic sheet covering the unit with
strapping to secure on the wooden pallet.
Specific earthing to insulate the earth
neutral point.
Advantages
Energy savings for applications which
require cooling all year round (e.g.:
industrial processes, data centres)
Energy savings for applications with
reduced demand for cooling in the winter
(e.g. office space with computer room,
meeting rooms, etc.)
Energy savings for applications which
require cooling all year round (e.g.:
industrial processes, data centres, etc.)
Glycol-free operation
Energy savings for applications with
reduced demand for cooling in the winter
(e.g. office space with computer room,
meeting rooms, etc.) Glycol-free operation
Avoids short cycle on compressors and
ensures stable water in the loop
Easy system management, control
capabilities extended to a drycooler used in
Free Cooling mode
Compliance with ESMA standard
UAE 5010-5:2019.
Compliance with KAHRAMAA regulations
in Qatar
Easy installation
for HVAC application in the EU
Compliance with Moroccan regulations
Prevents external dust and dirt from
contaminating the machine when storing
and transporting the unit.
The unit still operates after the first
electrical isolation fault to guarantee
continuity of operation (industrial processes,
data centres, hospitals).
IMPORTANT: The use of the hydraulic module on open
systems is prohibited.
12.2.2 - Hydraulic module with variable speed
(Options 116V, 116W)
The composition of the hydraulic module with variable speed is
similar to that of the hydraulic module without variable speed.
In this case, the pump is controlled by a variable frequency drive
that allows the pump's nominal flow rate to be adjusted according
to the chosen control mode (constant pressure or temperature
differential, or fixed speed) and the installation operating
conditions.
IMPORTANT: The use of the hydraulic module on open
systems is prohibited.
30RB/RBP
30RQ/RQP
170R-950R
165R-1040R
170R-950R 165R-1040R
170R-950R
No
170R-950R
No
170R-950R
No
170R-950R
No
170R-950R 165R-1040R
170R-950R 165R-1040R
170R-950R
No
170R-950R
No
No
620R-1040R
30RB
170R-380R
No
30RBP
170R-950R
170R-950R 165R-1040R
170R-950R 165R-1040R
170R-950R 165R-1040R