12 - OPTIONS

12.1 - Tables of options

Options
No.
Corrosion protection,
3A
traditional coils
Low-temperature
6B
brine solution
High static fans
12
Very low noise level
15LS
EC fans
17
Protection grilles
23
Soft starter per circuit
25E
Soft starter per
25
compressor
Water exchanger
41
frost protection
Water collection
41D Electric heater and insulation on the water
vessel frost
protection
Exchanger &
hydraulic frost
42A
protection
Exchanger and
hydraulic frost
42B
protection with buffer 
tank
Partial heat recovery
49
Total heat recovery
50
Master/slave
58
operation
Compressor suction
92A Shut-off valves on the common compressor 
and discharge valves
Evaporator
116R
single HP pump
HP dual-pump
116S
hydraulic module
Description
Fins made of pre-treated aluminium
(polyurethane and epoxy)
Low temperature chilled water production
down to -8 °C with ethylene or propylene
glycol
Unit equipped with high pressure static
variable-speed fans (maximum 200 Pa), 
each fan being equipped with a connection
flange for connection to the ducting system.
Acoustic compressor enclosure and
low-speed fans
Unit equipped with EC fans
Metallic protection grilles
Soft starter on each circuit
Electronic starter on each compressor
Electric heater on the water type heat
exchanger and the water duct
collection vessel pipes
Electrical heaters on the water type heat
exchanger, water pipes, hydraulic module
and expansion tank
Electrical heaters on the water type heat
exchanger, water pipes, hydraulic module
and optional expansion tank and buffer tank
Unit equipped with one desuperheater on
each refrigerant circuit
Unit equipped with additional heat
exchanger in series with the condenser
coils.
Unit equipped with supplementary water
outlet temperature sensor kit (to be field 
installed) allowing master/slave operation of 
two units connected in parallel
suction and discharge pipes
Evaporator hydraulic module equipped with
high pressure fixed-speed pump, 
drain valve, air vent and pressure sensors.
For more details, refer to the dedicated
chapter (expansion tank not included; 
option with built-in hydraulic safety
components available)
Dual high pressure water pump, water filter, 
electronic water flow rate control, pressure 
sensors.
For more details, refer to the dedicated
chapter (expansion tank not included; 
option with built-in hydraulic safety
components available)
Advantages
Improved corrosion resistance,
recommended for moderate marine and
urban environments
Covers specific applications such as ice 
storage and industrial processes
Ducted fan discharge, optimised
temperature control, based on the operating
conditions and system characteristics
Noise level reduction for sensitive sites
Improves the unit's energy efficiency
Coil protection against possible impact
Economical solution for reduced start-up
current
Reduced start-up current
Water type heat exchanger module frost
protection for an outdoor air temperature
between 0 °C and -20 °C
Water collection vessel frost protection
down to an outdoor temperature of -20°C
Water type heat exchanger and hydraulic
module frost protection down to an outdoor
air temperature of -20 °C
Water type heat exchanger and hydraulic
module frost protection down to an outdoor
air temperature of -20 °C
Production of free high-temperature hot
water simultaneously with chilled water
production (or hot water for heat pump)
Production of free hot water, adjustable on
demand
Optimised operation of two units connected
in parallel operation with runtime balancing
Simplified maintenance. Possibility to store 
the refrigerant charge in the cooler or
condenser side during servicing
Quick and easy installation (plug & play)
Quick and easy installation (plug & play)
30RB/RBP
30RQ/RQP
170R-950R
165R-1040R
No
165R-1040R
170R-950R
No
30RBP
30RQP
170R-950R
165R-1040R
170R-950R 165R-1040R
30RBP
30RQP
170R-950R
165R-1040R
170R-950R 165R-1040R
170R-950R 165R-1040R
170R-410R
165R-400R
170R-950R 940R-1040R
620R-940R
No
1040R
170R-950R 940R-1040R
170R-950R 940R -1040R
170R-950R 165R-1040R
30RBP
No
170R-950R
170R-950R
165R-520R
170R-950R 165R-1040R
30RB
170R-380R
165R-520R
30RBP
170R-550R
30RB
170R-380R
165R-520R
30RBP
170R-550R
65