12 - OPTIONS
Options
No. Description
Welded connection
sleeve for
304 DSH inlet/outlet welded connection sleeves Easy installation
desuperheater
Free cooling hydraulic coils on the two
Free cooling (total)
305A
refrigerant circuits
Free cooling hydraulic coils on a refrigerant
Free cooling (partial)
305B
circuit
Water buffer tank 
307 Built-in water buffer tank module
module
Free cooling mode
Control & connections to a Free Cooling
drycooler
313
Drycooler 09PE or 09VE fitted with option 
management
FC control box
Additional label on the unit with input
Compliance with
power, current and EER under rated
318
UAE regulations
conditions in accordance with
AHRI 550/590
Compliance with
Specific name plate on the unit with 415 V 
319
Qatar regulations
+/-6% power supply
Installation or
326 Specific management of option 
application process
compatibility
outside Europe
Compliance with
Moroccan regulations 327 Specific regulatory documentation
331 Unit wrapped in a plastic cover and
Plastic cover
strapped onto a wooden pallet.

12.2 - Description

12.2.1 - Hydraulic module without variable speed
(Options 116R, 116S, 116T, 116U)
The hydraulic module is composed of the system's main hydraulic
components:  factory-fitted  water  pump,  screen  filter  and  relief 
valve.
The fixed-speed operating pressure pump provides the nominal 
flow rate for the system water loop.
Several types of water pump are available to suit all applications:
- Single or dual low pressure pumps
- Single or dual high pressure pumps.
The nominal flow rate of the system should be adjusted using a 
manual control valve provided by the customer.
The relief valve placed on the water inlet pipes at the pump inlet
limits the pressure to 400 kPa (4 bar).
A screen filter that can be easily removed is placed at the pump 
inlet and protects the pump and the plate heat exchanger against
solid particles that are greater than 1.2 mm.
Advantages
Energy savings for applications which
require cooling all year round (e.g.: industrial 
processes, data centres)
Energy savings for applications with reduced
demand for cooling in the winter (e.g. office 
space with computer room, meeting rooms) 
Avoids short cycle on compressors and
ensures stable water in the loop
Easy system management, control
capabilities extended to a drycooler used in
Free Cooling mode
Compliance with ESMA standard
UAE 5010-5:2019.
Compliance with KAHRAMAA regulations
in Qatar
Permits non-standard option compatibility
for HVAC application in the EU
Compliance with Moroccan regulations
Protects against dust and external soiling of
the unit during storage and transport.
Additional options can be ordered if necessary:
- Option 42A (42B if option 307): hydraulic module protection 
(42A) or hydraulic module and buffer tank protection (42B) 
down to an outdoor temperature of -20 °C.
- Option 293: Expansion tank for water circulation system.
IMPORTANT: The use of the hydraulic module on open
systems is prohibited.
12.2.2 - Hydraulic module with variable speed
(Options 116V, 116W)
The composition of the hydraulic module with variable speed is
similar to that of the hydraulic module without variable speed.
In this case, the pump is controlled by a variable frequency drive
that allows the pump's nominal flow rate to be adjusted according 
to  the  chosen  control  mode  (constant  pressure  or  temperature 
differential,  or  fixed  speed)  and  the  installation  operating 
conditions.
IMPORTANT: The use of the hydraulic module on open systems
is prohibited.
30RB/RBP
30RQ/RQP
170-950
165-520
170-950
165-520
170-950
No
170-950
No
170-950
165-520
170-950
165-520
170-950
No
170-950
No
30RB
170R-380R
No
30RBP
170R-950R
170-950
165-520
170-950
165-520
55