Prepare For Heat Management - Heatilator RAVE32-IFT-B Installation Manual

Hide thumbs Also See for RAVE32-IFT-B:
Table of Contents

Advertisement

B. Prepare For Heat Management
Introduction
An optional heat management system allows the heat from
the appliance to be redirected as desired.
An optional heat management system must be installed by
a qualified service technician at the time of the appliance
installation. Follow the instructions shipped with the kit for
installation and operation.
NOTICE: Additional clearances are required for heat
management systems installations. Provisions must be
made in advance to ensure fit within the framing.
• Determine the heat management system(s) that will be
installed.
• Locate the two heat management ports on the top of the
appliance. Either one or two Heat-Zone
be installed. See Figure 6.2. Remove the knockouts
from the appliance with a tin snips.
• Center the duct collar or passive heat adapter around
the exposed hole and attach it to the appliance. See
Figure 6.5.
Note: Do this BEFORE final positioning of the appliance.
• Determine the location for the air register/fan housing
assembly.
Reference the Heat-Zone
Kit, Heat-Duct Kit, Heat-Out-Gas Kit or Passive Heat
instructions for the remaining installation steps.
Heat Management System options are:
HEAT-ZONE
-GAS:
®
adjacent room.
• HEAT-OUT-GAS: The heat is diverted outside the
home/building.
• Smart-Wall™ TV Kit: The warm air from the appliance
is conveyed through an air duct to remote locations in
the same room or other rooms of the building.
• Passive Heat (PH-LINEAR): The heat is vented into
the room in which the appliance is installed through a
discharge opening(s).
The
RAVE-IFT-B
models
Management Systems, but not all are compatible.
The HEAT-OUT-GAS kit may be used with either HEAT-
ZONE
-GAS or one of the Passive Heat options.
®
Passive Heat may be used with HEAT-OUT-GAS or
one HEAT-ZONE
-GAS. The dedicated knockouts, as
®
shown in Figure 6.5, must be used only as indicated.
Passive Heat cannot be used with the Smart-Wall TV Kit
or optional fan.
Heatilator • RAVE32-IFT-B, RAVE36-IFT-B, RAVE42-IFT-B Installation Manual • 2619-983 Rev. U • 9/22
-Gas Kits may
®
-Gas Kit, Smart-Wall™ TV
®
The heat is diverted into an
may
utilize
two
Smart-Wall™ TV Kit
When a Smart-Wall™ TV Kit is installed, only one Heat-
Zone
-Gas kit or one Heat-Out-Gas kit may be installed.
®
The Smart-Wall™ TV Kit can not be used with a power
vent option or optional fan.
WARNING! Risk of Fire! DO NOT block passive heat
registers!
materials will occur.
WARNING! Risk of Fire! DO NOT remove a knockout
unless a heat management system will be installed in its
place. Appliance and combustible materials will overheat.
REMOVE KNOCKOUTS
Figure 6.5 Proper Positioning, Leveling And Securing Of
Appliance
Heat
Overheating of appliance and combustible
41

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rave36-ift-bRave42-ift-b

Table of Contents