D. Use of Elbows
Diagonal runs have both vertical and horizontal vent as-
pects when calculating the effects. Use the rise for the
vertical aspect and the run for the horizontal aspect. See
Figure 4.6.
Two 45º elbows may be used in place of one 90º elbow.
On 45º runs, one foot of diagonal is equal to 8-1/2 inch
(216 mm) horizontal run and 8-1/2 inch (216 mm) vertical
run. A length of straight pipe is allowed between two 45º
elbows. See Figure 4.6.
Figure 4.7 shows the vertical and horizontal offsets for
SLP elbows.
VERTICAL
Effective Length
SLP
Pipe
Inches
Millimeters
SLP4
4
SLP6
6
SLP12
12
SLP24
24
SLP36
36
SLP48
48
1219
SLP6A
3 to 6
76 to 152
SLP12A
3 to 12
76 to 305
Figure 4.6
Heatilator • RAVE32-IFT-B, RAVE36-IFT-B, RAVE42-IFT-B Installation Manual • 2619-983 Rev. U • 9/22