EB-S01/W01/X14G/S11/X11/S02/S02H/X02/W02/S12/S12H/X12/W12/X14 EH-TW480
Error code/error name
SE
Sensor error
SEIKO EPSON
Faulty part/part name
TH Board is broken.
TH Cable is not connected properly.
TH Board (1)/(2)
TH Cable
TH Cable is broken.
Elements for temperature control on
MA Board
MA Board are broken.
Troubleshooting
Cause
Replace the broken TH Board.
Connect the cable to MA Board correctly.
Replace the broken cable.
If the error continues after carrying out the remedies
above, the related circuit on MA Board is broken, so
replace MA Board.
36
CONFIDENTIAL
Remedy
• "2.4.6 Cable Connection
and Projector's Status
(p46)"
• "3.3.6 MA Board
(assembly) (p74)"
• "3.3.10.1 TH Board (2) /
EX Fan (p88)"
• "3.3.12.1 IR Board
(p97)"
"3.3.6 MA Board (assembly)
(p74)"
Reference
Revision C