a.
Remove the top cover. See "Remove the top cover" on page 376.
b.
If your server comes with an air baffle, a middle cage, or a rear cage, remove it first.
• "Remove the air baffle" on page 196
• "Remove the middle drive cage" on page 271
• "Remove the rear 2.5-inch drive cage" on page 329
• "Remove the rear 3.5-inch drive cage" on page 336
c.
If your server has an CFF adapter or a RAID super capacitor installed on the front of the
chassis, remove it first.
• "Remove an internal CFF adapter" on page 238
• "Remove a super capacitor from the chassis" on page 313
d.
Record where the cables are connected to the system board; then, disconnect all the cables.
e.
Remove any of the following components that are installed on the system board and put them
in a safe, static-protective place.
• "Remove a system fan" on page 364
• "Remove the system fan cage" on page 368
• "Remove a memory module" on page 250
• "Processor and heat sink replacement (trained technician only)" on page 297
• "Remove the CMOS battery" on page 205
• "Remove a PCIe adapter and riser assembly" on page 284
• "Remove the OCP 3.0 Ethernet adapter" on page 277
f.
Pull out the power supplies slightly. Ensure that they are disconnected from the system board.
Step 2.
Remove the system board.
Figure 288. System board removal
a.
Lift the two release pins at the same time.
b.
Slide the system board towards the front of the chassis until it stops.
c.
Tilt and lift the system board out of the chassis.
After you finish
.