Lenovo ThinkSystem SR650 V2 Maintenance Manual page 259

Hide thumbs Also See for ThinkSystem SR650 V2:
Table of Contents

Advertisement

Step 4.
Install the M.2 adapter into the M.2 tray.
Figure 194. M.2 adapter installation
1. Open the retention clip on the air baffle.
2. Insert the M.2 adapter at an angle of approximately 30 degrees into the tray.
3. Rotate the M.2 adapter downward into place.
4. Close the retention clip.
5. Tighten the screw to secure the M.2 boot adapter.
6. Connect the cables to the M.2 adapter.
7. Tighten the screw that secures the M.2 signal cable to the M.2 adapter.
Step 5.
Install the M.2 drive on the M.2 adapter.
Figure 195. M.2 drive installation
1. Insert the M.2 drive at an angle of approximately 30 degrees into the connector.
2. Rotate the M.2 drive down until the notch
3. Slide the retainer forward (toward the connector) to secure the M.2 drive into place.
Step 6.
Connect the cables to the system board. See "M.2 drives" on page 83.
After you finish
Use the Lenovo XClarity Provisioning Manager to configure the RAID. For more information, see:
https://sysmgt.lenovofiles.com/help/topic/lxpm_frontend/lxpm_v3_about.html
catches on the lip of the retainer