RUGGEDCOM RS401
Installation Manual, 11/2022, C79000-G8976-1017-12
Braided Ground Cable
4
Figure 2.10
Terminal Block Wiring
Connect the negative wire from the power source to the negative/neutral (-/N)
on the terminal block.
Using a braided wire or other appropriate grounding wire, connect the surge
ground terminal to the chassis ground connection. The surge ground terminal
is used as the ground conductor for all surge and transient suppression circuitry
internal to the unit.
Connect the ground terminal on the power source to the chassis ground
terminal on the device. For more information, refer to
Device" (Page
14).
Installing the Device
2.6.2 Connecting DC Power
"Grounding the
17