Water Purge Setting - Scotsman Prodigy Elite MC0322 Service Manual

Air, water, and remote cooled modular cuber
Table of Contents

Advertisement

MC0322 through MC2148
Air, Water, and Remote Cooled Service Manual

Water purge setting

The water purge is factory set to the Automatic setting. The setting can be changed to one of 5 manual settings
or placed on automatic. The purge setting shows in the Code Display.
purge setting
1 - Minimum
Water Type
RO water or
equivalent,
TDS less than
35
To set:
Switch the machine OFF by holding the Off button in until a number or the letter A shows on the display.
Press and release the On button repeatedly until the number on the display corresponds to the desired setting.
Press and release the Off switch again to return to the normal control state.
Product Description and Electrical Requirements
See user's manual, dataplate, or spec sheet for Minimum Circuit Ampacity or Maximum Fuse Size
Ratings include the remote condenser motor, as it is designed to be powered by the ice machine. If connecting
remote condenser independently of the ice machine, use the information on the condenser's dataplate for fuse
and wire sizes.
2 - Moderate
3 - Standard
Low TDS non
Setting for
- RO water
typical water
January 2022
Page 8
4 - Heavy
5 - Maximum
High TDS
Very high
water
TDS water,
greater than
256
A - Automatic
Any with
conductivity not
less than 10
microSiemens/
cm

Advertisement

Table of Contents
loading

Table of Contents