Diagnostics - Water Cooled - Scotsman Prodigy Elite MC0322 Service Manual

Air, water, and remote cooled modular cuber
Table of Contents

Advertisement

MC0322 through MC2148
Air, Water, and Remote Cooled Service Manual
Diagnostics – Water Cooled
No ice
Problem
No power to unit
No power to controller
Shut down on maximum
water fill time
Shut down on maximum
freeze time
Likely Cause
Power disconnected Check breaker or fuse.
Reset or replace, restart and check
Transformer open
Water shut off
Water leak
Ice thickness sensor dirty or disconnected
Water distributor dirty
Inlet water valve leaks through during freeze
Connected to hot water
Incomplete harvest
High pressure cut out opened
Fan motor pressure control open
Fan motor not turning
Water pump not pumping
Pump hose disconnected
Compressor not operating
Low refrigerant charge
Hot gas valve leaks through during freeze
Thermostatic expansion valve bulb loose
Thermostatic expansion valve producing very
low or very high superheat
Compressor inefficient
January 2022
Probable Solution
Replace transformer
Restore water supply
Check purge valve, curtain, sump, pump
hose
Check ice thickness sensor probe
Remove and clean water distributor
Check inlet water valve
Check for bleed thru from / missing check
valve in building water supply
Check harvest system
Water supply cut off, restore water supply
to condenser
Check fan pressure control
Check fan motor, check fan blade, check
controller using test mode
Check pump motor, check controller
using test mode
Check hose
Check compressor contactor, check
controller using test mode
Check compressor start
components, check PTCR
resistance and temperature
Check compressor voltage
Check compressor windings
Add some refrigerant and restart unit. If
cycle time improves, look for leak.
Check hot gas valve for hot
outlet during freeze
Check bulb
Check evaporator superheat, change
TXV if incorrect
Check compressor amp draw, if low and
all else is correct, change compressor
Page 40

Advertisement

Table of Contents
loading

Table of Contents