Scotsman Prodigy Elite MC0322 Service Manual

Scotsman Prodigy Elite MC0322 Service Manual

Air, water, and remote cooled modular cuber
Table of Contents

Advertisement

Quick Links

Service Manual for
Air, Water, and Remote Cooled Modular Cuber
Prodigy Elite® Models MC0322, MC0522,
MC0722, MC0330, MC0530, MC0630, MC0830,
MC1030, MC1448, MC1848, MC2148

Advertisement

Table of Contents
loading

Summary of Contents for Scotsman Prodigy Elite MC0322

  • Page 1 Service Manual for Air, Water, and Remote Cooled Modular Cuber Prodigy Elite® Models MC0322, MC0522, MC0722, MC0330, MC0530, MC0630, MC0830, MC1030, MC1448, MC1848, MC2148...
  • Page 2: Table Of Contents

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Introduction This technical manual covers the Prodigy line, excluding the Eclipse remote low side models. All are shipped with an Installation and User's manual, which can be referred to separately. General installation information is included in this manual.
  • Page 3: Model Number Description

    Scotsman reserves the right to make design changes and/or improvements at any time. Specifications and design are subject to change without notice.
  • Page 4: Water

    Testing has shown that using a filter that does not remove chlorine, such as the Scotsman Aqua Patrol, will greatly improve this situation, while the ice making process itself will remove the chlorine from the ice, resulting in no taste or odor impact.
  • Page 5: General Installation - Air Or Water Cooled

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual General Installation - Air or Water Cooled Location Limitations: The product is designed to be installed indoors, in a controlled environment. Air cooled models discharge very warm air into the room out the back. Space must be allowed at the left side and back for air intake and discharge.
  • Page 6 MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual General Installation - Air or Water Cooled Plumbing Requirements All models require connection to cold, potable water. A hand actuated valve within site of the machine is required. Air cooled models have a single 3/8” FPT inlet water connection. Water cooled models have the same inlet fitting plus an additional 3/8”...
  • Page 7: Adjustments

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Adjustments Ice Bridge Thickness 1/8 to 3/16 inch bridge Too Thick Too Thin Correct Correct Small Medium Caution: Do not make the bridge too thin or the machine will not harvest properly. Bridge thickness adjustments are not covered by warranty.
  • Page 8: Water Purge Setting

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Water purge setting The water purge is factory set to the Automatic setting. The setting can be changed to one of 5 manual settings or placed on automatic. The purge setting shows in the Code Display. purge setting 1 - Minimum 2 - Moderate...
  • Page 9: General Installation - Remote

    RCKCME6GX-E. • Fan motor on all the time or controlled to be on whenever the ice machine is operating. • Non-Scotsman condensers must have prior Scotsman Engineering approval for warranty coverage to be in effect. Precharged tubing kits: The ice making head’s and the remote condenser’s refrigeration circuits must be connected.
  • Page 10: General Installation - Remote

    • Horizontal Run = hd x 1 (hd = distance in feet) • Calculation: Drop(s) + Rise(s) + Horizontal Run = dd+rd+hd = Calculated Line Length Configurations that do NOT meet these requirements must receive prior written authorization from Scotsman. Do NOT: •...
  • Page 11: General Installation - Remote

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual General Installation - Remote For The Installer: Remote Condenser Locate the condenser as near as possible to the interior location of the ice machine. Note: The location of the condenser is relative to the ice machine is LIMITED by the specification on the prior page.
  • Page 12 MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual General Installation - Remote Do not connect the refrigerant tubing until all routing and forming of the tubing is complete. Final connections requires brazing, steps must be performed by an EPA certified type II or higher technician. The Lineset of tubing contains a 3/8”...
  • Page 13 MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual General Installation - Remote Plumbing Requirements All models require connection to cold, potable water. A hand actuated valve within site of the machine is required. Water Filters Install a new cartridge if the filters were used with a prior machine. All models require drain tubing to be attached to them.
  • Page 14: Prodigy Cuber System Information

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Prodigy Cuber System Information Overall System Type: • Refrigeration: Mechanical, either air cooled, water cooled or remote cooled. • Water System: Inlet water solenoid valve fills reservoir once per cycle. Purge solenoid valve opens to discharge some reservoir water once per cycle.
  • Page 15: Controller Information

    Code Display Main codes - automatically displayed Scan QR code to download the Scotsman ICELINQ™ App: F ..Freeze Cycle Connect to this machine via Bluetooth to access additional machine operations, F flashes .
  • Page 16: Component Indicator Lights

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Component Indicator Lights • Condenser Fan / Aux (Aux = liquid line solenoid when a remote condenser model) • Water Pump • Purge Valve • Water Solenoid • Hot Gas •...
  • Page 17: How It Works - Air Cooled

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual How It Works - Air Cooled Freeze Cycle. At start up the controller drains and refills the reservoir. The reservoir refills when the mid length water level sensor probe is uncovered and continues to fill until the top probe is in contact with water. When the reservoir has filled, the compressor and water pump start.
  • Page 18: How It Works - Water Cooled

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual How It Works - Water Cooled Freeze Cycle. At start up the controller drains and refills the reservoir. The reservoir refills when the mid length water level sensor probe is uncovered and continues to fill until the top probe is in contact with water. When the reservoir has filled, the compressor and water pump start.
  • Page 19: How It Works - Remote

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual How It Works - Remote Freeze Cycle. At start up the controller drains and refills the reservoir. The reservoir refills when the mid length water level sensor probe is uncovered and continues to fill until the top probe is in contact with water. When the reservoir has filled, the liquid line valve, compressor and water pump are switched on.
  • Page 20: Electrical Sequence - Air Or Water Cooled

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Electrical Sequence - Air or Water Cooled Power connected, unit previously switched Off. Control board does a self check. If the self check fails, the unit displays an E and no further action will occur. If the self check passes, the controller will display a 0, the curtain light(s) will be ON and the Power and Sump Empty lights will be ON.
  • Page 21: Electrical Sequence - Remote Cooled

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Electrical Sequence - Remote Cooled Power connected, unit previously switched Off. Control board does a self check. If the self check fails, the unit displays an E and no further action will occur. If the self check passes, the controller will display a 0, the curtain light(s) will be ON and the Power and Sump Empty lights will be ON.
  • Page 22: Remote Schematics

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Remote Schematics Remote Condenser Head Pressure Control Valve Discharge Line Receiver Hot Gas Valve Heat Exchange Suction Compressor Remote Condenser Hot Gas Valve Head Pressure Control Valve Discharge Line Suction Receiver Hot Gas Valve...
  • Page 23: Electrical Component Details

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Electrical Component Details Compressor • Operated by the compressor contactor. Single phase self contained models have PTCR and run capacitor. Contactor • Operated by the controller and the high pressure cut out switch. Line voltage coil. When energized the Compressor indicator light will be ON.
  • Page 24 MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Electrical Component Details Liquid Line Valve • Remote only. Opened by the controller to start a freeze cycle. Closed to shut unit off. Line voltage coil. Hot Gas Valve(s) • Operated by the controller in parallel with the harvest assist solenoid. Cycles on and off at the beginning of a restart.
  • Page 25 MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Electrical Component Details Discharge temperature sensor. • Thermistor attached to the discharge line near the compressor. Reported temperature used by the controller to determine end-of-cycle-fan-off-delay time. If discharge temperature exceeds a preset maximum, controller will shut the machine off.
  • Page 26: Refrigeration

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Refrigeration • Refrigerant: R-404A • Compressors: Copeland or Tecumseh hermetic by model • Expansion valves: Non adjustable, internally equalized, one per evaporator. • Hot gas valves: Pilot operated, line voltage coils. One per plate. •...
  • Page 27: Water System

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Water System • Batch type. Insulated water reservoir contains full water charge for each ice making cycle. • Water valve: Solenoid type. Opens to fill reservoir when mid sensor probe no longer makes a circuit to the bottom probe.
  • Page 28: Control Operation

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Control Operation Standard control: • Electronic controller operating from a 12 AC volt power supply. Will operate within a voltage range between 10 and 15.5. • User’s Indicator lights, four front visible: Power, Status, Water, De-scale/Sanitize. •...
  • Page 29: Control Safeties

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Control Safeties Max freeze time – 45 minutes When exceeded, the controller will attempt another freeze cycle. If the next cycle's freeze time is less than maximum, the control will continue normal ice making. If the next freeze cycle was too long, the control will again attempt another freeze cycle.
  • Page 30: Control Button Use (From Standby)

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Control Button Use (from standby) Set purge level, 1-5 (1 is minimum, 5 is maximum) or Automatic: • Hold off button in for 3 seconds. Release. • Press and release the On button to cycle through and select one of the five purge settings or to use the Automatic setting.
  • Page 31: Control Button Use - Continued

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Control Button Use - continued Change De-Scale Notification Interval Like the others, this feature is accessible only from standby (Status Light Off). 1. Press and hold harvest button for 3 seconds. Starts the Time to Clean Adjustment State and displays the current time to clean setting.
  • Page 32: Thermistor Values

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Thermistor Values Deg. F Ohms Deg. F Ohms Deg. F Ohms Deg. F Ohms Deg. F Ohms 85325 19381 5569 1927 82661 18873 5446 1890 80090 18381 5325 1855 77607 17903 5208 1819...
  • Page 33: Cleaning

    For step by step instructions on how to perform a full maintenance cleaning, see User Manual or download the Scotsman ICELINQ® app, available on both the Apple App Store and Google Play Store. January 2022 Page 33...
  • Page 34: Critical Maintenance - Water Level Sensor

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Critical Maintenance - Water Level Sensor During use the Water Level Sensor may become coated with mineral scale from the water, which if left untreated can negatively impact machine performance. To correct, the Water Level Sensor must have the mineral scale removed.
  • Page 35: Critical Maintenance - Ice Thickness Sensor

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Critical Maintenance - Ice Thickness Sensor The freeze cycle is controlled by an ice thickness sensor positioned in front of the ice making surface. It is triggered by water contact. Water contacts the sensor when the ice is at the proper size.
  • Page 36: Critical Maintenance - Spillway

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Critical Maintenance - Spillway The freeze cycle on a Prodigy cuber is controlled by an ice thickness sensor positioned in front of the ice making surface. It is triggered by water contact. Normally water only contacts the sensor when the ice is at the proper size.
  • Page 37: Diagnostics - Air Cooled

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Diagnostics – Air Cooled No ice Problem Likely Cause Probable Solution No power to unit Power disconnected Check breaker or fuse. Reset or replace, restart and check No power to controller Transformer open Replace transformer Shut down on maximum...
  • Page 38 MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Diagnostics - Air Cooled Problem Likely Cause Probable Solution Shut down on Ice bridge thickness too small, not enough ice Check and adjust if needed maximum harvest time to open curtain Ice bridge thickness too large, ice frozen to Check and adjust if needed evaporator frame...
  • Page 39: Low Ice Making Capacity - Air Cooled

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Low Ice Making Capacity - Air Cooled Problem Likely Cause Probable Solution Long freeze cycle Dirty air filters Clean filters Dirty condenser Clean condenser Hot ambient Reduce room air temperature Water leak Check purge valve, check curtain Water inlet valve leaks through...
  • Page 40: Diagnostics - Water Cooled

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Diagnostics – Water Cooled No ice Problem Likely Cause Probable Solution No power to unit Power disconnected Check breaker or fuse. Reset or replace, restart and check No power to controller Transformer open Replace transformer Shut down on maximum...
  • Page 41 MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Diagnostics - Water Cooled Problem Likely Cause Probable Solution Shut down on Ice bridge thickness too small, not enough ice Check and adjust if needed maximum harvest time to open curtain Ice bridge thickness too large, ice frozen to Check and adjust if needed evaporator frame...
  • Page 42: Low Ice Making Capacity - Water Cooled

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Low Ice Making Capacity - Water Cooled Problem Likely Cause Probable Solution Long freeze cycle Dirty air filters Clean filters Dirty condenser Clean condenser Hot ambient Reduce room air temperature Water leak Check purge valve, check curtain Water inlet valve leaks through...
  • Page 43: Diagnostics - Remote Air Cooled

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Diagnostics – Remote Air Cooled No ice Problem Likely Cause Probable Solution No power to unit Power disconnected Check breaker or fuse. Reset or replace, restart and check No power to controller Transformer open Replace transformer Shut down on maximum...
  • Page 44 MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Diagnostics - Remote Air Cooled Problem Likely Cause Probable Solution Shut down on Ice bridge thickness too small, not enough ice Check and adjust if needed maximum harvest time to open curtain Ice bridge thickness too large, ice frozen to Check and adjust if needed evaporator frame...
  • Page 45: Low Ice Making Capacity - Remote Air Cooled

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Low Ice Making Capacity - Remote Air Cooled Problem Likely Cause Probable Solution Dirty condenser Clean condenser Hot ambient Check condenser inlet temp Water leak Check purge valve, check curtain Water inlet valve leaks through Check inlet valve Low on refrigerant...
  • Page 46: Test Procedures - Sensors

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Test Procedures - Sensors All electrical components in this ice machine can be diagnosed with a volt-ohmmeter. Curtain Switch: 1. Test using the controller’s indicator lights. Observe SW1 and SW2. Open and close the curtain in question. When the curtain is opened, the SW light will be ON.
  • Page 47: Ice Thickness Sensor

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Ice Thickness Sensor 1. Test using the controller’s indicator light. Observe the Ready To Harvest light. Shut the machine off. Use a wire to connect the metal part of the Ice Thickness sensor to the evaporator or simply remove the Ice Thickness Sensor and touch its metal surface to the metal control box wall.
  • Page 48: Water Level Sensor

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Water Level Sensor 1. Test using the controller’s indicator lights (sump empty and sump full). Unit must be powered up and there must be water in the sump. Add some manually if needed. Locate water level sensor. Release from sump cover and slowly lift up until the mid-length probe is out of the water.
  • Page 49: Temperature Sensors

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Temperature Sensors 1. Check controller. If the sensor calibration is completely out of range, the code display will read either 5 or 7. 2. Check with an ohmmeter. • Open control box cover, unplug sensor from J6. Water temperature probe: •...
  • Page 50: Test Procedures - Compressor

    Most Scotsman service compressors include those parts. Some systems use a potential start relay and start capacitor in place of the PTCR.
  • Page 51: Test Procedures - Fan Motor

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Test Procedures - Fan motor 1. Test using the controller’s indicator lights. Note: Fan pressure control connection must be jumped to perform this test. Put the controller into test mode (depress Off for 3 seconds then depress Clean for 3 seconds). At the end of the test cycle, the fan motor will be powered and the Condenser Fan motor indicator light will be on.
  • Page 52: Test Procedures - Water Pump

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Test Procedures - Water Pump 1. Test using the controller’s indicator lights. Check the indicator light during the freeze cycle. The light will be On for all but the 30 second anti-slush period, so observe the light for one minute. When it is On, check the water pump, it should be operating.
  • Page 53: Test Procedure - Purge Valve

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Test Procedure - Purge valve 1. Test using the controller’s indicator lights. • Shut unit off by holding the Off button for 3 seconds. Wait four minutes. • Push and release the On button, observe the Purge Valve indicator light. As the unit drains the reservoir, the purge valve will be powered.
  • Page 54: Test Procedure - Compressor Contactor

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Test Procedure - Compressor contactor 1. Test using the controller’s indicator lights. When the unit is in ice making mode (continuous F in the display) the compressor contactor will have power. •...
  • Page 55: Test Procedures - Pressure Switches

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Test Procedures - Pressure switches There are two pressure switches: Fan and High Pressure cut out. Fan. The fan pressure switch will open to shut the fan motor off at a certain pressure and re-close at a preset higher pressure.
  • Page 56: Test Procedures - Liquid Line Solenoid

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Test Procedures - Liquid Line Solenoid 1. Test using the controller’s indicator lights. Put the controller into test mode (depress Off for 3 seconds then depress Clean for 3 seconds). At the end of the test cycle, the liquid line valve will be powered and the Condenser Fan motor indicator light will be on.
  • Page 57: Test Procedure - Inlet Water Solenoid Valve

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Test Procedure - Inlet Water Solenoid Valve 1. Test using the controller’s indicator lights. Shut unit off by holding the Off button for 3 seconds. Wait four minutes. Push and release the On button, observe the Water Solenoid indicator light. After the unit drains the reservoir, the inlet water valve will be powered to refill the reservoir.
  • Page 58: Test Procedure - Harvest Assist

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Test Procedure - Harvest Assist 1. Test using the controller’s indicator lights. Push and release the Harvest button. The Hot Gas indicator light will be on. At the same time the Harvest Assist Solenoid or Motor will be powered. If the ice on the evaporator is thin, the ejection pin will extend.
  • Page 59: Repair Section

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Repair Section Inlet Water Solenoid Valve 1 Disconnect electrical power Electrical Shock Hazard Disconnect electrical power before beginning 2 Shut off the water supply. 3 Remove front and left side panels. 4 Unplug wire from coil.
  • Page 60 7 Reverse to reassemble. Note: Solenoid replaced by mechanism beginning in 2013. Solenoid prior to 2010 may be eligible for recall. See www.scotsman-ice.com for details 2010 and later Harvest Assist Solenoid Harvest Assist Mechanism, use began 2013 January 2022...
  • Page 61: Repair Section

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Repair Section Ice thickness sensor 1. Push and release the Off switch. 2. Remove front and top panels. 3. Push and release the Harvest switch 4. Remove the evaporator cover. 5.
  • Page 62: Repair Section

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Repair Section Capacitor (run) 1. Disconnect electrical power. 2. Remove front panel. 3. Open control box cover. 4. Remove right side of control box. 5. Remove metal barrier from control box 6.
  • Page 63: Repair Section

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Repair Section Controller 1. Disconnect electrical power. Electrical Shock Hazard Disconnect electrical power before beginning 2. Remove front panel. 3. Open control box door. 4. Unplug all wires from controller. 5.
  • Page 64: Repair Section

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Repair Section Curtain • Push and hold the Off button to shut the machine off. • Remove front panel. • Remove evaporator cover. • Push inside tab in to release front curtain pin from holder. •...
  • Page 65: Repair Section

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Repair Section Purge valve 1. Push and hold the Off button to shut the machine off. 2. Disconnect electrical power. Electrical Shock Hazard Disconnect electrical power before beginning 3. Remove front panel. 4.
  • Page 66: Repair Section

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Repair Section Water pump 1. Push and hold the Off button until the machine shuts off. Electrical Shock Hazard Disconnect electrical power before beginning 2. Remove the front panel. 3. Unplug the water pump 4.
  • Page 67: Refrigeration Removal And Replacement

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Refrigeration Removal and Replacement Evaporator 1. Remove panels as needed for evaporator access. 2. Remove evaporator cover. 3. If the machine was in operation, push and release the Harvest button to warm up the evaporator. 4.
  • Page 68 MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Refrigeration Removal and Replacement Compressor 1. Remove front panel. 2. If the machine was in operation, push and release the Harvest button to shut it down. Wait until the harvest cycle has ended so the evaporator has no ice on it.
  • Page 69: Refrigeration Removal And Replacement

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Refrigeration Removal and Replacement Thermostatic Expansion Valve 1. Remove front panel. 2. If the machine was in operation, push and release the Harvest button to shut it down. Wait until the harvest cycle has ended so the evaporator has no ice on it.
  • Page 70: Optional Add-On Control Information - Kvs

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Optional add-on control information - KVS Vari-Smart™ or KVS Adjustable ice level option The adjustable ice level control is an optional add-on system consisting of an control board, label and sensor. The control board fits above the standard control and connects to it using connector J4.
  • Page 71: Performance Data

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Performance Data MC0522A MC0522W MC0722A MC0322A MC0322W Ice production (lb /24 hr @ 90/70) Ice production (lb /24 hr @ 70/50) Water use, gallons ice only Ice weight / cycle (lb) 2.4-2.6 2.4-2.6 4.8-5.2...
  • Page 72: Performance Data

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Performance Data January 2022 Page 72...
  • Page 73 MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Performance Data January 2022 Page 73...
  • Page 74: Performance Data

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Performance Data January 2022 Page 74...
  • Page 75: Performance Data

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Performance Data January 2022 Page 75...
  • Page 76: Performance Data

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Performance Data January 2022 Page 76...
  • Page 77 MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Performance Data January 2022 Page 77...
  • Page 78: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Wiring Diagram MC0322, MC0722, MC0330, MC0530, MC0630 A/W Single Phase January 2022 Page 78...
  • Page 79: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Schematic Diagram MC0322, MC0722, MC0330, MC0530, MC0630 A/W Single Phase January 2022 Page 79...
  • Page 80 MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Wiring Diagram MC0522, MC0830, MC1030 A/W Single Phase January 2022 Page 80...
  • Page 81: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Schematic Diagram MC0522, MC0830, MC1030 A/W Single Phase January 2022 Page 81...
  • Page 82: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Wiring Diagram MC0530, MC0630 Remote Single Phase January 2022 Page 82...
  • Page 83: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Schematic Diagram MC0530, MC0630 Remote Single Phase January 2022 Page 83...
  • Page 84: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Wiring Diagram MC0830 Air Three Phase January 2022 Page 84...
  • Page 85: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Wiring Diagram MC0830 Air Three Phase January 2022 Page 85...
  • Page 86: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Wiring Diagram MC1030 Remote Three Phase January 2022 Page 86...
  • Page 87: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Schematic Diagram MC1030 Remote Three Phase January 2022 Page 87...
  • Page 88: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Wiring Diagram MC0830, MC1030 Remote Single Phase January 2022 Page 88...
  • Page 89: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Schematic Diagram MC0830, MC1030 Remote Single Phase January 2022 Page 89...
  • Page 90: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Wiring Diagram MC2148 Remote Single Phase January 2022 Page 90...
  • Page 91: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Schematic Diagram MC2148 Remote Single Phase January 2022 Page 91...
  • Page 92: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Wiring Diagram, MC1448 Air Water Single Phase January 2022 Page 92...
  • Page 93: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Schematic Diagram, MC1448 Air Water Single Phase January 2022 Page 93...
  • Page 94: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Wiring Diagram MC1448 Remote Single Phase January 2022 Page 94...
  • Page 95: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Schematic Diagram, MC1448 Remote Single Phase January 2022 Page 95...
  • Page 96: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Wiring Diagram MC1448 Air Water Three Phase January 2022 Page 96...
  • Page 97: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Schematic Diagram, MC1448 Air Water Three Phase January 2022 Page 97...
  • Page 98: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Wiring Diagram MC1448 Remote Three Phase January 2022 Page 98...
  • Page 99: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Schematic Diagram MC1448 Remote Three Phase January 2022 Page 99...
  • Page 100: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Wiring Diagram MC330L, MC430L Single Phase January 2022 Page 100...
  • Page 101: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Schematic Diagram MC330L, MC430L Single Phase January 2022 Page 101...
  • Page 102: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Wiring Diagram MC222L Single Phase January 2022 Page 102...
  • Page 103: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Schematic Diagram MC222L Single Phase January 2022 Page 103...
  • Page 104: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Wiring Diagram MC2148 Remote Three Phase January 2022 Page 104...
  • Page 105: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Schematic Diagram MC2148 Remote Three Phase January 2022 Page 105...
  • Page 106: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Wiring Diagram MC2148 Remote Single Phase January 2022 Page 106...
  • Page 107: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Schematic Diagram MC2148 Remote Single Phase January 2022 Page 107...
  • Page 108: Wiring Diagrams

    MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Wiring Diagram, MC2648 Remote Single Phase January 2022 Page 108...
  • Page 109 MC0322 through MC2148 Air, Water, and Remote Cooled Service Manual Wiring Diagrams Schematic Diagram, MC2648 Remote Single Phase January 2022 Page 109...
  • Page 110 SCOTSMAN ICE SYSTEMS 101 Corporate Woods Parkway Vernon Hills, IL 60061 800-726-8762 www.scotsman-ice.com...

Table of Contents