Key considerations
• Correct location is critical to a successful application.
• Avoid reflective interference from vessel walls and obstructions by following the
guidelines below.
Internal damage
• Do not remove factory lock screw.
• Do not rotate upper wave guide with respect to housing or internal change may occur.
4.3

Nozzle design

• Bottom edge of horn must project from nozzle.
• Nozzle must allow adequate clearance to allow positioning if LR460 has to be at an angle
so that emission cone perpendicular to material surface.
SITRANS LR460
Operating Instructions, 10/2021, A5E42035355-AB
WARNING
Upper wave guide
Factory lock screw
Min clearance: 10 mm (0.4")
Installing/mounting
4.3 Nozzle design