Installation and disassembly
4.2 Types of installation
If the temperature at the cable or housing socket or at the branching points of the cables
exceeds 60 °C, special precautions must be taken. If the equipment is operated at ambient
temperatures in excess of 40 °C, only use cables with permitted operating temperature of at
least 80 ℃.
Further notes
NOTICE
Warming and premature aging of the network component due to direct sunlight
Direct sunlight can heat up the device and can lead to premature aging of the network
component and its cabling.
Provide suitable shade to protect the network component against direct sunlight.
4.2

Types of installation

Types of installation
The device can be installed in the following ways:
• DIN rail
• S7-300 mounting rail
• S7-1500 mounting rail
• Wall mounting
Installation clearance
Keep to the minimum clearances so that the convection ventilation of the device is not
blocked.
• Below at least 10 cm
• Above at least 10 cm