Requirements; Setting Up The Ml628 Board - Xilinx IBERT ML628 Getting Started Manual

Hide thumbs Also See for IBERT ML628:
Table of Contents

Advertisement

Requirements

Requirements
The hardware and software required to run the GTX or GTH IBERT demonstrations are:
The hardware and software required to rebuild the IBERT demonstration designs are:

Setting Up the ML628 Board

This section describes how to set up the ML628 Virtex-6 FPGA GTH and GTX Transceiver
Characterization Board.
Caution!
ESD prevention measures when handling the board.
When the ML628 board ships from the factory, it is configured for the GTH and GTX IBERT
demonstrations described in this document. If the board has been re-configured it must be
returned to the default set-up before running the IBERT demonstrations.
1.
6
ML628 Virtex-6 FPGA GTH and GTX Transceiver Characterization Board including:
Two CF cards containing the IBERT demonstration designs ( IBERT #1 and
IBERT #2)
One Samtec BullsEye cable
Eight SMA female-to-female (F-F) adapters
Eight SMA (female-to-male) DC Blocks (optional)
GTH transceiver power supply module (installed on board)
GTX transceiver power supply module (installed on board)
SuperClock-2 module (installed on board)
Active BGA Heatsink (installed on FPGA)
12V DC power adapter
JTAG cable:
Platform Cable USB (Xilinx part number DLC9, DLC9G, or DLC9LP) or,
Platform Cable USB II (Xilinx part number DLC10) or,
Parallel Cable IV (Xilinx part number PC4)
Host PC with:
CF card reader or PCMCIA adapter card for CF cards
USB ports
Xilinx® ChipScope™ Pro software, version 13.1 or higher.
Software is available at:
http://www.xilinx.com/chipscopepro
Xilinx ISE® Design Suite version 13.1 or higher
PC with a version of the Windows operating system supported by Xilinx ISE Design
Suite
ML628 IBERT demonstration design source files (provided online as collection
rdf0117_13-1.zip) at:
http://www.xilinx.com/products/boards/ml628/reference_designs.htm
The ML628 board can be damaged by electrostatic discharge (ESD). Follow standard
Move all jumpers to their default positions. The default jumper positions are listed in
UG771, ML628 Virtex-6 FPGA GTX and GTH Transceiver Characterization Board User
Guide.
www.xilinx.com
ML628 IBERT Getting Started Guide
UG806 (v1.0) May 20, 2011

Advertisement

Table of Contents
loading

Table of Contents