Cleaning And Maintenance; Troubleshooting - Dometic 9600001410 Operating Manual

Compressor fridge & freezer
Table of Contents

Advertisement

CFX75DZW, CFX95DZW
8

Cleaning and maintenance

!
WARNING!
Always disconnect the device from the power supply before you clean
and service it.
A
NOTICE! Risk of damage
Never clean the cooler under running water or in dish water.
Do not use abrasive cleaning agents or hard objects during cleaning
as these can damage the cooler.
➤ Occasionally clean the device interior and exterior with a damp cloth.
➤ Make sure that the air inlet and outlet vents on the device are free of any dust and
dirt, so that heat can be released and the device is not damaged.
9

Troubleshooting

Fault
Device does not
function, LED does
not glow.
The device does not
cool (power is
connected, "POWER"
LED is lit).
The device does not
cool (power is
connected, "POWER"
LED flashes orange,
display is switched off).
EN
Possible cause
No voltage was
detected in the DC
power outlet.
No voltage present in
the AC voltage outlet.
The device fuse is
defective.
The integrated mains
adapter is defective.
Defective compressor.
Battery monitor is set
too high.
Battery voltage is too
low.
Cleaning and maintenance
Suggested remedy
In most vehicles the ignition must be
turned on before power will be sup-
plied to the DC power outlet.
Try using another plug outlet.
Replace the device fuse, see chapter
"Replacing the AC fuse" on page 25.
This can only be repaired by an
authorised repair centre.
This can only be repaired by an
authorised repair centre.
Select a lower battery monitor setting.
Test the battery and charge it as
needed.
27