Settings - Aprilaire S86N MU Manual

Multi-stage universal thermostat with iaq
Hide thumbs Also See for S86N MU:
Table of Contents

Advertisement

TABLE 1 – HVAC INSTALLER SYSTEM SETTINGS
System setting
Description
Select No to skip the rest of the
Advanced HVAC

Settings?

thermostat settings
Progressive
Enables or disables progressive recovery
Recovery
Select if the Heat Blast option is
Display Heat Blast?
displayed
Amount of heating when Heat Blast is
Heat Blast Offset
initiated
Extended Fan –
Extends fan operation 90 seconds after
Heat
heat call ends
Extended Fan –
Extends fan operation 90 seconds after
Cool
cool call ends
Enable or disable Auto Changeover
Auto Changeover
mode
20
Factory default setting
(bold) and setting range
No
Yes
Disabled
Enabled
No
Yes
3°F (1.5°C)
4°F (2°C)
5°F (25°C)
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
TABLE 1 – HVAC INSTALLER SYSTEM SETTINGS
System setting
Description
DeadBand
Auto Changeover mode deadband
Auto Changeover
Minimum time between heating and
Time
cooling calls
Field adjustment of controlling
Temp Sensor Offset
temperature sensors
Internal RH sensor Increases or
RH Sensor Offset
decreases displayed RH%
Equipment
Minimum on time for heating and
Minimum On Time
cooling
Heating Minimum
Minimum off time for heating
Off Time
Compressor
Minimum off time for compressor
Minimum Off Time
protection
Factory default setting
(bold) and setting range
3°F (1.5°C)
2 to 9°F (1 to 45°C)
4 Minutes
1 to 5 Minutes
0°F (0°C)
-4 to 4°F (-2 to +2°C)
0
-5 to 5
2 Minutes
1 to 5 Minutes
2 Minutes
1 to 5 Minutes
5 Minutes
1 to 5 Minutes