Aprilaire 8600 Safety & Installation Instructions

Aprilaire 8600 Safety & Installation Instructions

Universal touch screen thermostat
Hide thumbs Also See for 8600:

Advertisement

TAblE Of CONTENTS

INSTAllATION
Installation location recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Outdoor temperature sensor (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Remote temperature sensor (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Thermostat mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Power & reset options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Wiring terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
Equipment type selection switch (SW1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Installer setup menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
System test menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
REfERENCES
Quick reference to controls & display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Error codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Thermostat features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
61000729A 8600 Tstat Install.indd 1
Model 8600 Universal
Touch Screen Thermostat
Safety &
Installation
Instructions
READ AND SAVE THESE INSTRUCTIONS
10/8/10 10:32:26 AM

Advertisement

Table of Contents
loading

Summary of Contents for Aprilaire 8600

  • Page 1: Table Of Contents

    Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 61000729A 8600 Tstat Install.indd 1...
  • Page 2: Installation Location Recommendations

    • Using less than 300’ of wire. locked out and only the heat pump will be used to • Do not route wires along 120 VAC lines. provide heating. B O Y Y2 G L S2 61000729A 8600 Tstat Install.indd 2 10/8/10 10:32:28 AM...
  • Page 3: Remote Temperature Sensor (Optional)

    90 seconds with no battery or AC power. The reset button located under the battery cover can be used to reset the thermostat to factory defaults. The system settings will also be reset to default . 61000729A 8600 Tstat Install.indd 3 10/8/10 10:32:31 AM...
  • Page 4: Wiring Terminal

    (see wiring diagrams). CONVENTIONAl HEAT/COOl SINglE TRANSfORMER (USE JUMpER wIRE) TwO TRANSfORMERS (REMOVE JUMpER wIRE) RC R W2 S1 T1 T2 RC R W2 S1 T1 T2 61000729A 8600 Tstat Install.indd 4 10/8/10 10:32:35 AM...
  • Page 5: Setup & Testing

    The thermostat will discard changes and exit if nothing is pressed within 60 seconds . SETTING SETTING To reset the installer settings to the default, reset the DESCRIPTION NUMBER thermostat by pressing the [RESET] key . SETTING OPTIONS 61000729A 8600 Tstat Install.indd 5 10/8/10 10:32:41 AM...
  • Page 6 In this setting, the heat pump will lock out before the fossil fuel auxiliary heat comes on; eliminating the need for a dual fuel kit. If utilizing electric auxiliary heat, set to Electric. In this setting, the heat pump and electric auxiliary heat are allowed to run simultaneously. 61000729A 8600 Tstat Install.indd 6 10/8/10 10:32:42 AM...
  • Page 7 0 – 100% 40. Daylight savings Enable or disable auto daylight savings March (second Sunday in March to the first Sunday in November) April (first Sunday in April to the last Sunday in October) 61000729A 8600 Tstat Install.indd 7 10/8/10 10:32:42 AM...
  • Page 8: System Test Menu

    Note: Second stage will only be displayed when the thermostat is set to multi-stage mode . STAGE Test Number System test Heating equipment test Cooling equipment test Auxiliary equipment test (HP only) Fan equipment test 61000729A 8600 Tstat Install.indd 8 10/8/10 10:32:43 AM...
  • Page 9 Test 62: Auxiliary Equipment Test (HP only) button Equipment Heat press Type Type 1st Up Heat Pump press Electric 2nd Up Heat Pump press Electric Test 63: Fan Equipment Test button press 1st Up press 61000729A 8600 Tstat Install.indd 9 10/8/10 10:32:44 AM...
  • Page 10: Quick Reference To Controls & Display

    MAIN MENU CLEAN SCREEN (LOCKOUT TOUCH SCREEN FOR 30 SECONDS) SET VACATION HOLD (HOLD–TO TIME AND DATE) SET CURRENT TIME SET SCHEDULE BUTTON SET CURRENT DATE DONE BUTTON (EXIT MENU) USER SYSTEM SETTINGS 61000729A 8600 Tstat Install.indd 10 10/8/10 10:32:51 AM...
  • Page 11: Troubleshooting

    If the error does not clear, use the reset button. This will return all settings back to factory default. Error code Message Error Description Open temperature sensor circuit “SENSOR ERROR” Shorted temperature sensor circuit “EEPROM ERROR” Error in permanent memory 61000729A 8600 Tstat Install.indd 11 10/8/10 10:32:51 AM...
  • Page 12: Thermostat Features

    Cool: 50° to 99°F (10° to 37°C) P.O. Box 1467 • Madison, WI 53701-1467 • Phone: 800/334-6011 • Fax: 608/257-4357 www.aprilairepartners.com 61000729 10 .10 B2205243A © 2010 Aprilaire – A division of Research Products Corporation 61000729A 8600 Tstat Install.indd 12 10/8/10 10:32:52 AM...

Table of Contents