Diagnostic Text Messages; Viewing The Test Log; Diagnostic Error Codes - IBM System x3755 Problem Determination And Service Manual

Hide thumbs Also See for System x3755:
Table of Contents

Advertisement

mouse test to test a USB mouse. You can run the USB interface test only if no USB
devices are attached. The USB test will not run if a Remote Supervisor Adapter II
SlimLine is installed.
To view server configuration information (such as system configuration, memory
contents, interrupt request (IRQ) use, direct memory access (DMA) use, device
drivers, and so on), select Hardware Info from the top of the screen.

Diagnostic text messages

Diagnostic text messages are displayed while the tests are running. A diagnostic
text message contains one of the following results:
Passed: The test was completed without any errors.
Failed: The test detected an error.
User Aborted: You stopped the test before it was completed.
Not Applicable: You attempted to test a device that is not installed in the server.
Aborted: The test could not proceed because of the server configuration.
Warning: The test could not be run. There was no failure of the hardware that was
being tested, but there might be a hardware failure elsewhere, or another problem
prevented the test from running; for example, there might be a configuration
problem, or the hardware might be missing or is not being recognized.
The result is followed by an error code or other additional information about the
error.

Viewing the test log

To view the summary test log when the tests are completed, select Utility from the
top of the screen and then select View Test Log. To view the detailed test log,
press Tab while the summary test log is displayed. The test-log data is maintained
only while you are running the diagnostic programs. When you exit from the
diagnostic programs, the test log is cleared.
To save the test log to a file on a diskette or to the hard disk, click Save Log on the
diagnostic programs screen and specify a location and name for the saved log file.
Notes:
1. To create and use a diskette, you must add an optional external diskette drive to
2. To save the test log to a diskette, you must use a diskette that you have

Diagnostic error codes

The following table describes the error codes that the diagnostic programs might
generate and suggested actions to correct the detected problems.
If the diagnostic programs generate error codes that are not listed in the table,
make sure that the latest levels of BIOS, Remote Supervisor Adapter II SlimLine,
and ServeRAID code are installed.
122
IBM System x3755 Type 8877 and 7163: Problem Determination and Service Guide
the server.
formatted yourself; this function does not work with preformatted diskettes. If the
diskette has sufficient space for the test log, the diskette can contain other data.

Advertisement

Table of Contents
loading

This manual is also suitable for:

88777163

Table of Contents