3.3

Nameplate layout

FUS060 transmitter identification nameplate
Figure 3-2
SITRANS FUS060 with HART
Operating Instructions, 09/2021, A5E01204521-AL
Code no.
Transmitter order number
Serial no.
Transmitter serial number
System no.
System order number
System S/N
System serial number
Temp Amb.
Ambient temperature range
PTB 07ATEX2033X Certification number
II 2 G
Marking
Ex db eb mb [ia Ga]
IIC T6...T3 Gb
II
Group II
2
Category 2 for use in Zone 1
G
For gas
Ex
Ex protection for use in explosive Atmosphere
db
Type of protection flame proof enclosure
eb
Type of protection increased safety
mb
Type of protection encapsulation
[ia GA]
Interface for circuits with type of protection intrinsic safety
IIC
Gas group IIC
T6...T3
Temperature class (read manual)
Gb
Protection level Gb for use in Zone 1
Year of Manuf.
Year of manufacture
FUS060 identification nameplate example