Introduction

1.10 Further Information

Special conditions for storage and transportation of the device are listed in Technical
specifications (Page 75).
The contents of this manual shall not become part of or modify any prior or existing agreement,
commitment or legal relationship. The sales contract contains all obligations on the part of
Siemens as well as the complete and solely applicable warranty conditions. Any statements
regarding device versions described in the manual do not create new warranties or modify the
existing warranty.
The content reflects the technical status at the time of publishing. Siemens reserves the right to
make technical changes in the course of further development.
1.9

How to read the Operating Instructions

These Operating Instructions describe only the installation of the FUS060 HART transmitter
(with HART interface). The flowmeter consists of a transmitter (FUS060) and a sensor (SONO
3100, SONO 3300 or SONOKIT) and is designed for measuring the flow velocity of liquids in full
pipes. Satisfactory function of the ultrasonic flowmeter depends on a low sound attenuation of
the medium and a well-defined and stable flow profile.
The installation of ultrasonic flowmeter system divided into 5 steps:
1. Selection of the measuring site
2. Installation of the sensor in the pipe (see separate sensor manual)
3. Mechanical installation of the transmitter (for example wall mounting)
4. Electrical connection of the transmitter
5. Electrical connection of the sensor transducers to the transmitter
Siemens Flow Instruments SITRANS F US ultrasonic flowmeters are designed for measurement
of:
• Volume or mass flowrate
• Limit monitoring
• Total volume or mass
• Sound velocity in the media
SITRANS F US ultrasonic flowmeters measure flow in standard volumetric and mass flow units.
Measurement is independent of changes in liquid temperature, density, pressure, and
conductivity. This ultrasonic flowmeter is designed for use on single phase liquids.
1.10
Further Information
Product information on the Internet
The Operating Instructions are available on the documentation disk shipped with the device,
and on the Internet on the Siemens homepage, where further information on the range of
SITRANS F flowmeters may also be found: