Storm Collar Installation (SC1)
Place storm collar over pipe and slide down until it is snug against
open edge of flashing (see Figure 15). Use SC1 for all round termina-
tions. Apply waterproof caulk around perimeter of collar to provide
a proper seal.
Chimney
Pipe
Storm
Collar
Figure 15 - Storm Collar
Terminations/Spark Arrestor
Fireplace system must be terminated with listed round top or chase
terminations. In any case, refer to installation instructions supplied
with termination. Terminations approved for this fireplace are RT-
8DM, RTL -8DM and RLT-8DM that can be used for flashing or chase
and ET-8DM, ETO-8DM, ETL-8DM and ETLO-8DM for chase style ter-
mination only. Figure 17 shows an RTL-8DM round top termination.
126625-01D
VENTING INSTALLATION Continued
flashing. Follow the installation instructions provided
with the termination being used.
Terminations with 16" slip pipe sections are available. RTT-8DM,
RTTL-8DM and RLTT-8DM are approved for flashing installations.
Waterproof
Caulk
When needed, these adjustable terminations may be used in combina-
tion with pipe assembly to achieve correct chimney height.
Flashing
Note: In the rare instance there is a problem with side driven rain or
wind or chimney is not drafting properly, an ADS-8DM (Anti-Draft
Shield) can be used with round terminations.
Attach Bracket
Tabs to
Outer Pipe
(3 Places)
Secure with
Screws
Overlap
Shingles Top
and Sides
Superiorfireplaces.US.com
CAUTION: Do not seal openings on the rooftop
Figure 16 - Termination
RTL-8DM
Level of Flue
Gas Outlet
Flue Pipe of
RTL-8DM
Inside Inner
Pipe of
Chimney
Caulk
Collar
Flashing
Underlap Shingles
Bottom Only
11