9

Reference Materials

A. Chimney Components
Catalog #
CAK4A
Chimney Air Kit
ID4
Insulated Duct/Outside Air
UD4
Uninsulated Duct/Outside Air
SL306
Chimney Section - 6 in. (152 mm) long
SL312
Chimney Section - 12 in. (305 mm) long
SL318
Chimney Section - 18 in. (457 mm) long
SL324
Chimney Section - 24 in. (610 mm) long
SL336
Chimney Section - 36 in. (914 mm) long
SL348
Chimney Section - 48 in. (1219 mm) long
SL3
Chimney Stabilizer
CAS8
Attic Shield Kit
SL315
Chimney Offset/Return - 15 deg
SL330
Chimney Offset/Return - 30 deg
FS338
Ceiling Firestop - Straight
FS339
Ceiling Firestop - 15 deg
FS340
Ceiling Firestop - 30 deg
SL300 Straight Attic Insulation Shield, 24 in. (610
AS8
mm)
JB877
Chimney Joint Band
CB876
Chimney Bracket
RF370
Roof Flashing - Flat to 6/12 Pitch
RF371
Roof Flashing - 6/12 to 12/12 Pitch
TR344
Round Termination Cap
TR342
Round Telescoping Termination Cap
ST375
Square Termination Cap
TV342
Top Vent Round Termination Cap
TS345
Square Termination Cap
TS345P
Square Termination Cap - Painted
TCT375
Terra Cotta Termination Cap
TR-TVK
TR Top Vent Kit
DTO134
Short Octagon Decorative Cap
DTO146
Tall Octagon Decorative Cap
DTS134
Short Square Decorative Cap
DTS146
Tall Square Decorative Cap
LDS33
Decorative Shroud - 3 ft x 3 ft (.91 m x .91 m)
LDS46
Decorative Shroud - 4 ft x 6 ft (1.22 m x 1.83 m)
Decorative Shroud - 26 in. x 26 in. (660 mm x 660
LDS-BV
mm)
Field Constructed Shrouds (See "Woodburning
Termination Cap")
CT-3A
Adapter - May be used with the following caps
CT Series
DT Series
Description
Heat & Glo • EM-415, EM-485T Installers Manual • 4017-268 • Rev S • 01/22
12 in.
(305 mm)
5-1/4 in.
(133 mm)
10-1/2 in.
(287 mm)
CAK4A Chimney Air Kit
A
8 in.
(203 mm)
B
Chimney Sections
Catalog #
in
SL306
6
SL312
12
SL318
18
SL324
24
SL336
36
SL348
48
A = Actual Length
B = Effective Length (length of
chimney part after it has
been snapped to another)
20-3/4 in.
(527 mm)
4-3/4 in. (121 mm)
Effective Height
SL3 Chimney Stabilizer
Attic Shield Kit
12 in.
(305 mm)
4 in. (102 mm)
10-1/2 in.
(267 mm)
A
B
mm
in
mm
152
4-3/4
121
305
10-3/4
273
457
16-3/4
425
610
22-3/4
578
914
34-3/4
883
1219
46-3/4
1187
Inside
Diameter
8 in.
(203 mm)
Outside
Diameter
10-1/2 in.
(267 mm)
Storm Collar
Attic Collar
Attic Spacer