Fireplace Setup; Gas Log/Lighter Provision; Wood Burning Inserts - Hearth and Home Technologies Heat & Glo EM-415 Installation Manual

Table of Contents

Advertisement

8

Fireplace Setup

A. Gas Log/Lighter Provision
WARNING! Fire and/or Asphyxiation Risk!
solid wood fuel or decorative gas appliance only. Gas fire
generates fumes.
Damper must be locked fully open when gas logs are
installed
A certified gas log lighter or decorative gas log set can be
installed in this fireplace.
Vented Gas Logs
Maximum input is 100,000 BTU/hr.
Decorative gas appliance must be certified to ANSI
Z21.60/CSA 2.26 "Standard for Decorative Gas
Appliances for Installation in Vented Fireplaces".
Must be installed in accordance with the National Fuel
Gas Code, ANSI Z223.1 and Natural Gas Installation
Code, CAN/CGA-B149.1-M95 or the Propane
Installation Code, CAN/CGA-B149.2-M95.
A gas log set must incorporate a gas shutoff.
Gas Log set requires the damper to be locked fully open.
A listed automatic damper system with safety interlock
may be used in this fireplace with only compatible,
listed gas log sets. See damper system manufacturer's
instructions.
Knockouts are provided on both sides of the fireplace
and in refractories for 1/2 in. (13 mm) iron pipe.
Seal refractory around pipe with fireplace mortar or a
non-combustible sealant.
Unvented Gas Logs
CAUTION! If an unvented gas appliance is installed in
the fireplace, the gas appliance must only be operated
with the fireplace glass door fully open (if included).
Only unvented gas log sets which have been found to
comply with the standard for unvented room heaters,
ANSI Z211.11.2, are to be installed in this fireplace. If
an unvented gas appliance is installed it must incorpo-
rate an automatic shutoff device, and must be installed
in accordance with the National Fuel Gas Code Z223.1,
Latest edition.
WARNING! Do Not operate an unvented gas log set in this
fireplace with the chimney removed.
34
Use with
Heat & Glo • EM-415, EM-485T Installers Manual • 4017-268 • Rev S • 01/22
B. Wood Burning Inserts
WARNING! Risk of Fire!
serts may cause fireplace or chimney system to overheat.
If a wood burning insert is being installed in this fireplace,
Hearth & Home Technologies recommends full reline of
the chimney.
DO NOT cover inlet or outlet grills.
Cooling air openings at the top of the chimney must not
be obstructed in any manner.
Hearth & Home Technologies recommends securing the
reline at the top of the flue and using the cap certified for
use with this fireplace system.
Firebox
Refractory
Seal with
fireplace mortar
or non-combust-
ible sealant
Gas line
Repack
insulation
knockout
(102 mm)
Figure 8.1
Gas Line Installation
Improper installation of wood in-
Outer shell
of fireplace
Maintain air clearance
to combustibles.
Combustible
materials
1 1/2 in. (38 mm)
air space around
pipe
Gas line
Combustible materials
may be located at zero
clearance to gas line
beyond 4 in. (102 mm)
from fireplace side.
4 in.

Advertisement