Toro DXi Installation And Setup Manual

Toro DXi Installation And Setup Manual

Wireless output board (wms only)

Advertisement

Quick Links

Document
373-1071
No:
Title:
Instruct, Install, Wireless Output Brd, DXI
Confidential Property of
Riverside, California
Re lease/Change Authorization
Number:
See subsequent pages for
Re v.
ECM No.
A
5174342
A
Rev:
0.08
Approx Weight:
8
Page count:
5174342
Printing instructions:
gray-scale
original PDF
REVISION SHEET
De scription of Change
Release to rev A
Issue Date :
11/8/2021
O riginator :
lbs
O riginating Location:
Drafter
Richard Keightley
1
Page:
Ri c h a rd K e ig ht l ey
Riverside
4
Sheet count:
Approved
Date
Shankara
11/8/2021
Raghuraman
By

Advertisement

loading

Summary of Contents for Toro DXi

  • Page 1 Document 373-1071 Rev: Issue Date : Page: 11/8/2021 Title: Instruct, Install, Wireless Output Brd, DXI Ri c h a rd K e ig ht l ey O riginator : Confidential Property of 0.08 Riverside Approx Weight: O riginating Location: Page count:...
  • Page 2 Selecting the Controller Installation Site The DXi wall-mount cabinet is designed for indoor or outdoor environments. Selecting an installation site that provides user accessibility as well as basic protection from extreme hot or cold environments is considered good installation practice.
  • Page 3 Connecting Input Power Wiring WARNING! THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION, INSTALLATION, AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. AC POWER WIRING MUST BE INSTALLED AND CONNECTED BY QUALIFIED PERSONNEL ONLY. ALL ELECTRICAL COMPONENTS AND INSTALLATION PROCEDURES MUST COMPLY WITH ALL APPLICABLE LOCAL AND NATIONAL ELECTRICAL CODES.
  • Page 4 Contact your 12” 12” 6 AWG (10mm local Toro distributor for assistance and availability of (30,5cm (30,5cm Bare Copper Wire the required earth ground resistance test instrument.
  • Page 5: Connecting Field Wiring

    Connecting Field Wiring Caution: The DXi WOB transformer is rated at 24 VAC, 50 VA. Each station output terminal is rated 24 VAC, 0.5A (max.) @ 77°F (25°C), and capable of operating more than one valve solenoid (typically 2 or 3).* Ensure the current load on any output does not exceed 0.5A.
  • Page 6: Connecting Sensors

    Connecting Sensors The DXi controller provides connection terminals for two flow sensors at the bottom of the WOB. One terminal is marked FLOW1, the other FLOW2 (see Figure 8). Caution: To prevent damage to the controller and/or sensor equipment, turn off power to the controller prior to connecting sensor wires.
  • Page 7 WOB only listens to the precode of its master. Once a board is in Training Mode, send a communication from the DXi TM by turning on any wireless output. All boards in Training Mode will learn the precode and stop flashing the LED. Make sure the switch is in the AUTO position. The output you turned on will turn on and the LED will light on the designated WOB, but all boards in Training Mode will have learned the precode.
  • Page 8 Command Interpreter (send radio commands to a specific WOB): • Used to set flow mode parameters on WOB and for general testing of communications and flow. • To send a command to a board, connect XTEND serial radio to laptop, and launch a terminal program (hypertrm is installed Windows XP).
  • Page 9: Fcc And Ic Statement

    émetteur. 5825 Jasmine Street Riverside, CA 92504 800-777-1477 irrigationsupport@toro.com WARNING: Cancer and Reproductive harm – www.P65Warnings.ca.gov. For more information, please visit www.toro.com/CAProp65. ©2021 The Toro Company • www.toro.com • Patents: www.ttcopats.com Part Number 373-1071 Rev. A...