Toro DXi Installation And Setup Manual page 3

Wireless output board (wms only)

Advertisement

Connecting Input Power Wiring
WARNING!
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION
CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION, INSTALLATION, AND OPERATION OF
THE PRODUCT AND THE HAZARDS INVOLVED.
AC POWER WIRING MUST BE INSTALLED AND CONNECTED BY QUALIFIED PERSONNEL ONLY.
ALL ELECTRICAL COMPONENTS AND INSTALLATION PROCEDURES MUST COMPLY WITH ALL APPLICABLE
LOCAL AND NATIONAL ELECTRICAL CODES. SOME CODES MAY REQUIRE A MEANS OF DISCONNECTION FROM
THE AC POWER SOURCE, INSTALLED IN THE FIXED WIRING, HAVING A CONTACT SEPARATION OF AT LEAST
3mm IN THE LINE AND NEUTRAL POLES.
ENSURE THE AC POWER SOURCE IS OFF PRIOR TO SERVICING. FAILURE TO COMPLY MAY RESULT IN SERIOUS
INJURY DUE TO ELECTRICAL SHOCK HAZARD.
Ensure the power is disconnected at the source.
1.
See Warning above.
Remove the terminal block cover, located below the transformer.
2.
Route the AC power and equipment ground wires through electrical
3.
conduit into the controller.
Strip wire ends to expose 3/8" (9,5mm) bare copper wire.
4.
Using a small flat-blade screwdriver, secure wires to the terminal
5.
connectors as shown in Figure 3 and as follows:
Line (black) to L, Neutral (white) to N, and Equipment Ground
(green) to the Gound Lug
Install and secure terminal block cover.
6.
Note: Do not apply power to the controller until all remaining
installation procedures have been completed
.
Figure 3