Download Print this page

Toro DXi Installation And Setup Manual page 2

Wireless output board (wms only)

Advertisement

DXi Wireless Output Board
Installation and Setup Guide
Selecting the Controller Installation Site
The DXi wall-mount cabinet is designed for indoor or outdoor environments. Selecting an installation site that provides
user accessibility as well as basic protection from extreme hot or cold environments is considered good installation practice.
At minimum, the installation site should provide the following:
Protection from direct exposure to irrigation spray, midday sun, and snow accumulation.
Access to all required wiring connections.
Access to a dedicated, single-phase AC power source.
Line of sight from the DXi controller, especially by metal walls or obstructions.
Installing the Wallmount Enclosure
Unlock and open the cabinet door, then open the hinged
1.
control panel. Position the controller on the wall at eye level,
and mark the top and bottom mounting screw locations.
See Figure 1.
Note: Two stainless steel screws are provided for installation to a
wall stud. If installing the controller on masonry or drywall, use
the appropriate type screw anchors and fasteners.
Install the screw anchors at 83/4" (22,23cm) (A) on center.
2.
! Caution: All cabinet openings required for installation
and wiring are provided. Drilling or cutting through the
cabinet should be avoided. Metal chips and filings entering
the cabinet can damage internal components.
Install the top mounting screw (B) leaving a 1/4" (6,4mm) gap
3.
between the screw head and wall.
Hang the controller on the mounting screw, ensuring the screw
4.
is located at the top of the cabinet keyhole slot. Install the lower
mounting screw (C), then tighten both screws securely.
Installing the Electrical Conduit
Remove wiring terminal block cover (1).
1.
Install electrical conduit from the power
source circuit breaker panel to the controller
location. Attach conduit to bottom of
cabinet using the 1/2" / 3/4" (13mm / 19mm)
access opening (2).
For field wiring, attach 2" or 3" (51mm
2.
or 76mm) conduit to cabinet using center
access hole (3).
An additional 1/2" / 3/4" (13mm / 19mm)
3.
access hole (4) is provided or auxiliary
wiring.
(WMS only)
Figure 1
Figure 2
1
2
C
F1 +
F1 -
F2 +
F2 -
ET +
ET -
RN +
RN -
24V
24V
COM
MV
PMP
3
B
A
4

Advertisement

loading