Appendix #2 Pin Configuration - Lorex L224 Series Instruction Manual

Triplex network digital video recorder
Hide thumbs Also See for L224 Series:
Table of Contents

Advertisement

APPENDIX #2
APPENDIX #2
PIN
FUNCTION
1
RS232-TX
2
RS232-RX
3~6
ALARM INPUT
7
EXTERNAL
ALARM NC
8
EXTERNAL
ALARM NO.
9
GND
10
RS485-B
11
RS485-A
12~13
PIN OFF
14
ALARM RESET
15
EXTERNAL
ALARM COM
16~17
GND
DC12V +
GND
8 7 6 5 4 3 2 1
DC12V +
15 14 13 12 11 10 9
GND
PIN Connection Application
PIN CONFIGURATION
PIN CONFIGURATION
DESCRIPTION
DVR can be controlled remotely by the keyboard of PC by using RS-232 serial
communication signals.
DVR can be controlled remotely by the keyboard of PC by using RS-232 serial
communication signals.
To connect the wire from ALARM INPUT ( PIN 3 -- 6 ) to GND ( PIN 9 )
connector, DVR will start recording and the buzzer will be on.
When "MENU -> CAMERA -> ALARM" is set to "Low" : When the alarm input
signal is " Low ", the unit starts to record and buzzer.
When "MENU -> CAMERA -> ALARM" is set to "High" : When the alarm input
signal is " High ", the unit starts to record and buzzer.
Under the normal operation, COM connects with NC and disconnects from NO.
But when any alarm is triggered, COM disconnects with NC and connects with
NO.
Attention: The voltage restriction is under AV/DC 30V.
Under the normal operation, COM disconnects with NO. But when any alarm is
triggered, COM connects with NO.
Attention: The voltage restriction is under AV/DC 30V.
Signal GND.
DVR can be controlled remotely by the keyboard of PC by using RS-485 serial
communication signals.
DVR can be controlled remotely by the keyboard of PC by using RS-485 serial
communication signals.
Connecting the wire from ALARM RESET (PIN 14) to GND (PIN 9) connector
will disable alarms. An external signal to ALARM RESET (PIN 14) can be used
to reset both ALARM OUTPUT signal and DVR's internal buzzer. When any
alarm has been triggered, the signal becomes "Low", and all alarm activities will
be stopped. Under the normal operation, the signal remains "High".
Under the normal operation, COM disconnects with NO. But when any alarm is
triggered, COM connects with NO.
Attention: The voltage restriction is under AV/DC 30V.
Earth GND
Solder Side
of DSUB
15PIN
16
17
When the magnetic contact is opened, the
alarm will be triggered and the recording is
on. At the same time, COM connects with
NO and the siren with strobe starts wailing
and flashing.
NOTE: Please go to MENU -> ADVANCE ->
DETECTION -> DETECTION SETUP, and
set ALARM to LOW on the local machine.
48