Various Control; Auto Restart; Manual Auto Operation (For Wall Mounted Type) - Fujitsu AUXG07KVLA Manual

2-unit multi-split type
Hide thumbs Also See for AUXG07KVLA:
Table of Contents

Advertisement

7. Various control

7-1. Auto restart

When the power was interrupted by a power failure etc. during operation, the operation contents at
that time are memorized and when the power is recovered, operation is automatically started with
the memorized operation contents.
Operation contents
memorized when the power is
interrupted
Operation mode
Setting temperature
Fan mode setting
Timer mode and set time
(set by wireless remote
controller)
Airflow direction setting
Swing
ECONOMY operation
10 °C HEAT operation
Outdoor low noise operation
Remote control setting
WLAN LED setting

7-2. MANUAL AUTO operation (For Wall mounted type)

When the wireless remote controller is lost or battery power dissipated, this function will work without
the remote controller.
When MANUAL AUTO button is pressed more than 3 seconds and less than 10 seconds, MANUAL
AUTO operation starts as shown in the table below. To stop operation, press the MANUAL AUTO
button for 3 seconds.
Operation mode
Fan mode
Timer mode
Setting temperature
Vertical airflow direction louver setting
SWING
ECONOMY
Human sensor
7-1. Auto restart
Wall mounted (For KGTE, KMCE,
KETA, and KETE)
Floor
- (04-74) -
Compact cassette,
Mini duct, Slim duct,
Wall mounted (For KGTB KMTB,
KMCC)
Auto changeover
AUTO
Continuous (no timer setting available)
24°C
Standard
Off
Off
Off
×
×
7. Various control

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents