Honeywell DACT-E3 Product Installation Document page 12

Digital alarm communicator transmitter
Table of Contents

Advertisement

Event
For Contact ID and SIA Formats:
NN
= In standalone systems, the group number assigned to the device (00-99).
= In networked systems, the node number where the device is located, (00-65).
= In multi-ring systems, the node number where the device is located, (000-122).
Note: Node numbers greater than 99 are truncated.
UUU = User-configured ID code (events originating from SLC devices using custom codes 001 = 899, if configured) or event type
code (used only for non-SLC device events). For details, see "Non-SLC Device Event Reporting Codes".
Note 1: Special AMM/PIDs include the following functions: Reset Switch, Silence Switch, Drill Switch, Alarm Acknowledge Switch, Trouble
Acknowledge Switch.
Note 2: In SIA format, two reports transmit the extended codes (if configured). See Notes 4 & 5.
Note 3: In 4/1 format, the "one's" digit of the user-assigned code is reported (if configured). See Notes 4 and Note 5.
Note 4: The UUU digits will always be 000 for events originating on the INI-7100, INI-VGC, INI-VGX, INI-VGE and NGA nodes.
Note 5: The DACT-E3 reports the node number and 000 as the "UUU" digits if an event occurs on an SLC device that does not have a user-
configured code assigned to it and the system is configured to report custom DACT codes.
Note 6: [ZZZ] indicates the Releasing Zone affected. It ranges from 943 to 950 (representing Releasing Zones 1-8).
Note 7: When [Z] is used for the 4/2 format, it may range from 3 to 0 (representing Releasing Zones 1-8). Releasing Zone 1 reports as 3, while
Releasing Zone 8 reports as 0.
Table 4.2.2.1 DACT-E3 Contact ID Event Reporting Codes for Custom Formats (Continued)
4.3 Reporting Codes for Non-SLC-Devices
For events that do not originate on SLC devices, the DACT-E3 reports extended codes in the range 900-999. These
codes are not user-configurable. Table 4.3.1 lists the extended codes.
Code
Event
000
Phone Line Test
001 - 899
SLC Device Codes
900
Programming Mode
901
SLC 1
902
SLC 2
903
NAC 1
904
NAC 2
905
Municipal Circuit
906
Aux Power Fault
907
Municipal Circuit Supervision
908
Positive Ground Fault
909
Negative Ground Fault
910
RS-232 Supervision Fault
911
Annunciator Fault
912
PM-9/PM-9G Supervision Fault
913
Battery Low
914
Battery Fault
915
AC Fault
916
DC Fault
917
Reserved
918
Battery Charger Fault
919
NAC 3, SLP Only
920
NAC 4, SLP Only
921
Access Fail
922
Silent Walk Test
923
Audible Walk Test
924
MNS Reset
925
DACT Account 1 Fault
926
DACT Missing
12
Contact ID and SIA Formates
Automatic DACT test OK
User-defined in device configuration
Programming
Loop Break, Short, or Disconnect
Loop Break, Short, or Disconnect
Fault, Short, or Disconnect
Fault, Short, or Disconnect
Master Box Trouble
Resettable or Non-Resettable B+ Fault
Table 4.3.1 Non-SLC Device Events Reporting Codes
DACT-E3 Product Installation Document — P/N 9000-0581:J6 12/16/2019
SIA
(See Note 2)
Contact ID
NOTES