Environmental Specifications; Operation Environment Specifications - Omron NC1-510000 User Manual

Amr controller
Table of Contents

Advertisement

4-3

Environmental Specifications

This section provides environmental specifications of the AMR Controller.
4-3-1

Operation Environment Specifications

The following table provides the general environmental specifications for the AMR Controller.
Item
Ambient operating temperature
Ambient storage temperature
Ambient operating humidity
Ambient storage humidity
Operating atmosphere
Altitude
Noise resistance (during operation)
Vibration resistance (during opera-
tion)
Shock resistance (during operation) Conforms to IEC 60068-2-27.
Pollution degree
RTC accuracy
*1.
Refer to 4-3-2 Temperature and Humidity Specifications on page 4-32 for ambient operating temperature
details per CPU type.
AMR Controller User's Guide (I650)
*1
0 to 55°C
*1
-20 to 70°C
10% to 90% with no condensation
10% to 90% with no condensation
No corrosive gases
2,000 m max.
Conforms to IEC61000-4-4, 2kV (power lines)
Conforms to IEC 60068-2-6.
147 m/s², 3 times in each X, Y and Z directions
JIS B3502 and IEC 61131-2: 2 or less
At ambient temperature of 55°C: −3.5 to +0.5 min error per month
At ambient temperature of 25°C: −1.5 to +1.5 min error per month
At ambient temperature of 0°C: −3 to +1 min error per month
4 Specifications
Specifications
4
4-31

Advertisement