Shutting Off The Engine; Using The Remote Control - Toro Pro Force 44553 Operator's Manual

Debris blower
Hide thumbs Also See for Pro Force 44553:
Table of Contents

Advertisement

Figure 15
1. LED light
2. Rotate left
3. Decrease engine speed
4. Engine start
Note:
There is a time limit of 3 seconds
between each button press. If the next button in
the sequence is not pressed within 3 seconds of
the last button press, the sequence is aborted
and must be started from the beginning.
If any button other than the next appropriate
button in the sequence is pressed the sequence
is aborted.
Note:
If the S
TART
10 seconds after pressing the R
button, or any other button is pressed in this
period, the Engine Start Enable Condition
expires.
Note:
Engine Start Enable Condition persists
for 10 seconds after pressing the R
button.
Note:
Pressing the S
extend this time period—the maximum length of
time that the Start Relay Control can be active
is 10 seconds from pressing the R
button.
After the Engine Start Enable Condition expires,
you must perform the Engine Start Enable
Sequence again in order to energize the Start
Relay Control with the S
cannot be performed for 10 seconds after the
S
button is released.
TART
Note:
If the sequence is aborted or the
Engine Start Enable Condition expires, normal
functionality of the R
L
buttons return to control the Chute Motor.
EFT
Important:
Do not engage starter for more
than 10 seconds at a time. If engine fails
to start allow 10 second cool-down period
5. Rotate right
6. Increase engine speed
7. Engine stop
button is not pressed within
R
OTATE
IGHT
R
OTATE
button does not
TART
R
OTATE
button. This
TART
R
and R
OTATE
IGHT
OTATE
between attempts. Failure to follow these
instructions can burn out starter motor.
4.
After the engine starts, move the choke control to
the O
FF
move the choke back to the O
few seconds, then set the engine speed to the
desired setting. Repeat this as required.

Shutting Off the Engine

1.
Decrease the engine speed to 3/4 throttle.
2.
Press the S
g029818
3.
If leaving the machine, rotate the key to the O
position and remove it from the ignition switch
(Figure

Using the Remote Control

The remote control activates (powers up) when any
push button is pressed. To conserve battery power,
the remote control stays active for approximately 3
seconds before automatically shutting down unless
there is button activity within the 3 second limit. When
the unit times out and powers down, all remote control
LED activity stops
reactivates the remote control
IGHT
IGHT
1. LED light
2. Rotate left
3. Decrease engine speed
4. Engine start
The RF2CAN and TEC2403 controllers revert to
Power Save Mode if the base unit is inactive for more
than 2.5 hours without communication from the remote
control. Power Save Mode is a low current state of
the machine. The machine does not communicate
with the remote control, does not activate outputs, and
does not function as normal.
18
position. If the engine stalls or hesitates,
button on the remote control.
TOP
14).
(Figure
16). Pressing any button
Figure 16
5. Rotate right
6. Increase engine speed
7. Engine stop
position for a
N
FF
g029818

Advertisement

Table of Contents
loading

Table of Contents