Download Print this page

Leviton VZE04-1L Installation Instructions page 2

Single pole (one location) or 3-way (multi-location) electronic low-voltage dimmer (lighted)

Advertisement

3-Way Wiring with Matching remote
step 4c
(w/LEDs) application:
Matching Remote
Dimmer
Additional
Green
Neutral Wire
Black
4
2
1
2
White
4
3
3
1
5
Red
5
Yellow/Red
Matching Remote (with LEDs)
Dimmer
Hot (Black)
WH
White
BK
Black
Electronic
Green
Black
Low-Voltage
Ground
Green
Ground
Yellow/
Transformer
Red
YL/RD
Red
Line
Primary
120VAC, 60Hz
Side
White
Neutral (White)
notE: Matching remotes are for use with non RF devices only.
notE: The dimmer must be installed in a wall box that has a Load
connection. The matching remote must be installed in a wall box
with a Line Hot connection and a Neutral connection. A Neutral wire
to the matching remote needs to be added as shown.
If you are unsure about any part of these instructions, consult a
qualified electrician.
notE: Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft (90 m).
WIrInG MatcHInG rEMotE
(wall box with Line Hot connection):
connect wires per WIrInG DIaGraM as follows:
• Green or bare copper wire in wall box to Green terminal screw.
• Line Hot (common) wall box wire identified (tagged) when
removing old switch and First Traveler to Black dimmer lead.
• Second Traveler wall box wire from dimmer to remote terminal
screw marked "YL/RD" (note wire color). This traveler from the
remote must go to Yellow/Red dimmer lead.
• Line Neutral wall box to remote terminal screw marked "WH".
WIrInG DIMMEr (wall box with Load connection):
connect wires per WIrInG DIaGraM as follows:
• Green or bare copper wire in wall box to Green dimmer lead.
• Load wall box wire identified (tagged) when removing old switch to
Red dimmer lead.
• First Traveler Line Hot to Black dimmer lead.
• Remove Red insulating label from Yellow/Red dimmer lead.
• Second Traveler wall box wire (note color as above) to
Yellow/Red dimmer lead. This traveler from the dimmer must go to
the terminal screw on the remote marked "YL/RD".
• Line neutral wall box wire to White dimmer lead.
• Proceed to step 5.
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton's only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof
of purchase date, and a description of the problem to Leviton Manufacturing co., Inc., att: Quality assurance Department, 59-25 Little neck Parkway, Little neck, new York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused,
opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. there are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness
for a particular purpose, is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
testing your Dimmer prior to mounting in
step 5
wall box:
• Position all wires to provide room in
outlet wall box for device.
• Ensure that the word "TOP" is facing
up on device strap.
• Partially screw in mounting screws in
wall box mounting holes.
notE: Dress wires with a bend as shown in diagram in order to relieve
stress when mounting device.
• Restore power at circuit breaker or
fuse.
• Press pad until locator light is OFF.
Lights should turn ON. If lights do
not turn ON, press the upper half of
the DIM/BRIGHT Bar until the lights
brighten.
If lights still do not turn on, refer to
the trouBLEsHootInG section.
Dimmer Mounting:
step 6
turn oFF PoWEr at cIrcuIt BrEaKEr or FusE.
Installation may now be completed by
tightening mounting screws into wall box.
Attach wallplate.
restore Power:
step 7
Restore power at circuit breaker or fuse.
Installation is complete.
oPEratIon
notE: The locator light will illuminate when the load is in the OFF
position to facilitate access in the dark.
notE: If using the dimmer in a 3-way application, the lights will turn
ON at brightness set on dimmer's DIM/BRIGHT bar. The lighting can be
controlled from either the dimmer or the remote location.
Push Pad (Default settings)
LED
DIM/
Brightness
BrIGHt
turn on from oFF position:
Display
Bar
Tap – Lights turn ON to preset level.
Press and Hold – Lights turn ON to full
bright.
turn oFF from on position:
Tap – Lights turn OFF.
DIM/BrIGHt Bar
BrIGHtEn:
Press the upper half of the DIM/BRIGHT
Bar – Lights brighten to desired level.
DIM:
Press the lower half of the DIM/BRIGHT
Bar – Lights dim to desired level.
If you continue to hold, the lights will DIM
to minimum level and then turn OFF.
notE: When lights are OFF you can
change the light level that the lights will
turn ON to using the DIM/BRIGHT Bar.
If there is a power outage, when the power
Push
Locator
is restored, the lights will return to the last
Pad
Light
setting before the power interruption.
air-Gap switch: On the dimmer only, engage
the air-gap switch by gently pulling the bottom
of the push pad until it lifts completely out of
the frame and a click is heard and all LED's are
OFF (refer to figure). This will cut power to
the fixture to replace the bulb. After servicing is
complete, push the push pad back for normal
operation.
cleaning: Clean with a damp cloth.
Do not use chemical cleaners.
Gently lift bottom
of push pad out
aDVancED ProGraMMInG FEaturEs
Mode 1 – set Minimum Brightness: Set the minimum brightness level
that the lights can dim to prior to turning full OFF.
Mode 2 – set Dim-Lock: Set the brightness level that the lights will turn
on to regardless of the previous light level at which they were turned OFF.
Mode 3 – set Fade rate: Set the amount of time (in seconds) that the
lights will have to turn ON or OFF. Fade rates can be set to one of seven
different settings.
advanced Features summary
Mode
Description
range
Default
1
Set Min. Brightness
1 - 50 %
25 %
0 - 100 %,
2
Set Dim-Lock Level
0
0 = no lock
3
Select Fade Rate
1, 2, 3, 4, 5, 6 or 7
Preset #1
LIMItED 5 YEar WarrantY anD EXcLusIons
to Program:
notE: Have a flashlight handy if this
dimmer controls the only light source in
the room.
1. On the dimmer only, engage the
air-gap switch by gently pulling the
bottom of the push pad until it lifts
completely out of the frame and a
click is heard and all LED's are OFF.
2. Press push pad back into frame and
hold the push pad for 7 seconds until
the locator light and the top LED
(LED 1) start blinking.
3. Upon releasing the push pad, the
locator light will continue to blink once per second indicating the
dimmer is in Mode 1, Set Minimum Brightness mode. To change the
minimum Brightness level from 1-50%, use the DIM/BRIGHT Bar.
This setting will automatically be saved.
4. Tap the push pad to change to Mode 2, Set Dim-Lock Level
mode. The locator LED will blink twice per second. To change the
current Dim-Lock level from 0-100%, use the DIM/BRIGHT Bar.
If this feature is not desired, press and hold the lower half of the
DIM/BRIGHT Bar until no LED is lit. This setting will automatically be
saved.
5. Tap the push pad to change to Mode 3, Set Fade Rate mode. The
locator LED will blink 3 times per second. To change the current
Fade Rate, use the DIM/BRIGHT Bar to move the LED to the desired
preset level. This setting will automatically be saved by tapping the
push pad to exit programming mode.
The LED Brightness Display is separated into 7 segments. Each LED
represents a preset level with LED 1 (Preset 1) located at the top and
LED 7 (Preset 7) located at the bottom. Refer to chart for settings and
defaults.
notE: The dimmer will exit program mode after 3 minutes of inactivity.
Fade rate Presets
Preset
LED**
Fade on
Fade off
1*
1
Approx. 1.5s from full off
Approx. 3s from full on
2
2
No Fade
No Fade
3
3
No Fade
Approx. 3s from full on
4
4
Approx. 0.5s from full off
Approx. 3s from full on
5
5
Approx. 0.5s from full off
Approx. 1.5s from full on
6
6
Approx. 1.5s from full off
Approx. 5s from full on
7
7
Approx. 1.5s from full off
Approx. 10s from full on
*
default
**
LED #1 is located at the top
1
2
LED
3
Brightness
4
Display
5
6
7
trouBLEsHootInG
• Lights Flickering
- Lamp has a bad connection.
- Wires not secured firmly with wire connectors of dimmer or
terminal screws of remote.
- Verify load type is electronic low-voltage.
• Light does not turn on and Locator LED does not turn on
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Neutral not wired to Dimmer (White wire).
• Intermittent dimmer operation
- Minimum load is under 40W.
• remote does not operate lights
- Ensure that total wire length does not exceed 300 ft (90 m).
- Ensure wiring is correct.
• Lights cycle on and oFF
- Remove excess load.
For additional information, contact Leviton's
techline at 1-800-824-3005 or visit Leviton's
website at www.leviton.com
Covered by one or more US & Foreign Patents and patents pending
Copyright© 2006 Leviton Manufacturing Co., Inc.
All Rights Including Trade Dress Rights Reserved
Fcc coMPLIancE
statEMEnt
This equipment has been tested and found to comply with the limits for
a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined
by turning the equipment OFF and ON, the user is encouraged to try to
correct the interference by one or more of the following measures:
• Reorient or relocate the receiving Antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
• Consult the dealer or an experienced radio/tv technician for help.
PK-93392-10-00-2C

Advertisement

loading

This manual is also suitable for:

Vze06-1l