Leviton Topaz 12 User Manual page 18

Portable pack and associated control modules
Hide thumbs Also See for Topaz 12:
Table of Contents

Advertisement

After you have made all necessary settings on the Universal Control Module, you can install it into the TOPAZ 12 pack.
Push the module in firmly making sure that the edge connectors are making full contact.
Multiplex control wiring to this module is via the 5-pin XLR connectors on the back of the Pack. See Figure 10. If
LEVITON control cables are not available, cables can be made using Neutrik NC5MX-B (male) and NC5FX-B (female), or
equivalent connectors and Belden 9829, or equivalent cable. Connector wiring is as shown in Table 7, depending on the
position of the AMX/DMX Switch discussed in Setup Step 5, above.
*Depends on the setting of the Status/Other Switch - see control module setup, Step 4.
Plug the control console into the male connector marked "In" for the first pack. Plug the male end of a jumper cable into
the pack connector marked "Out" and the other end of the cable into the next pack. Packs can be connected in any order
without regard to the thumbwheel switch-selected dimmer numbers. If operating in the DMX mode, the complete
installation must adhere to the EIA 422A standard, which, in general, limits the total cable length to 1000' (304.8m) and
the number of Control Modules to 16. Systems operating in the AMX mode must comply with the USITT AMX-192
standard.
Now you can go on to the Final Assembly section of this manual, Chapter V.
Multiplex Control Connector Wiring
Wiring
Shield
Pair 1
Pair 1
Pair 2
Pair 2
TABLE 7
Pin
AMUX
1
C-ND
2
CLOCK-
3
CLOCK+
4
ANALOG MUX.
5
NOT USED
Figure 10 - Control Connectors
Page 16
FUNCTION
DMX512/CMX
GND
DATA-
DATA+
NOT USED
NOT USED
Control Out – To next pack
Control In - From console or another pack