2. RESET SWITCH (Front Panel, Figure 7)
If a control module becomes inoperative or "freezes", the Reset Switch should be pressed. This will cause a "warm boot"
of the system and it should resume normal operations.
3. TEST SWITCH (Front Panel, Figure 7)
This switch is used to test the individual outputs of each dimmer without the use of a signal from a lighting console. This
switch, when in the up position, causes all the dimmers to lock on at full. By shutting off all the breakers and turning each
breaker on individually, you can check the output of each dimmer. This switch overrides any signal coming into the pack
and must be turned off (down) to restore dimmer control to the lighting console.
4. STATUS ONLY / OTHER CONSOLE SWITCH (Front Panel, Figure 7)
IMPORTANT: This switch should be used ONLY when using a Status control console;
moving the switch and using any other control console may damage that control console.
By placing the switch in the "Status Only" position, you are placing 12 volts on pin #4 of the data cable. For all other types
of digital control consoles, the switch must be in the "Other Console" position (down) only. The switch should be checked
before a lighting console is connected.
5. AMX / DMX SWITCH (Front Panel, Figure 7)
This switch is used to switch between DMX512 and AMX192 protocols.
DMX POSITION
In this position, the control module will receive USITT standard DMX512 and will automatically switch
between CMX and DMX512 protocol.
AMX POSITION
In this position, the control module will receive USITT standard AMX192 protocol.
IMPORTANT: This switch extensively changes the function of the control connector on the rear of the pack.